SPLIT TYPE
ROOM AIR CONDITIONER
WALL MOUNTED
type
Models Indoor unit Outdoor unit
ASYA07LCC
ASYA09LCC
ASYA12LCC
ASYA14LCC
ASYA18LCC
ASYB09LDC
ASYB12LDC
AOYR07LCC
AOYR09LCC
AOYR12LCC
AOYR14LCC
AOYR18LCC
AOYS09LDC
AOYS12LDC
INVERTER
SERVICE
INSTRUCTION
R410A

Other manuals for Fujitsu ASYA09LCC

Questions and Answers

  • F
    Frances KennedySep 4, 2025
    What does serial reverse transfer error during the operation mean for Fujitsu ASYA09LCC Air Conditioner?
    • J
      Joshua ChenSep 4, 2025
      If your Fujitsu Air Conditioner displays a serial reverse transfer error during operation, it means the indoor unit isn't receiving a signal for 10 seconds. Check the indoor/outdoor cable connection. If the wiring is normal, measure the voltage of the outdoor unit terminals and diagnose the defective location.
  • D
    David CookSep 18, 2025
    Why Fujitsu Air Conditioner has power supply frequency detection error?
    • S
      Suzanne FloresSep 18, 2025
      If your Fujitsu Air Conditioner displays a power supply frequency detection error, it means the power supply frequency cannot be recognized after 4 seconds of power ON. The Controller PCB might be defective.
  • E
    Eugene HoltSep 16, 2025
    What does forced auto switch error mean on Fujitsu ASYA09LCC?
    • P
      Paul LyonsSep 16, 2025
      If your Fujitsu Air Conditioner displays a forced auto switch error, it means the forced auto switch has been ON for 30 consecutive seconds. Check if the forced auto switch is kept pressed. The forced auto switch might be defective or the Controller PCB might be defective.
  • M
    Mark ShafferSep 14, 2025
    What to do if my Fujitsu ASYA09LCC Air Conditioner shows outdoor temperature thermistor error?
    • A
      Allison ReynoldsSep 14, 2025
      If your Fujitsu Air Conditioner displays an outdoor temperature thermistor error, it means the detection value of the outdoor temperature thermistor is either open or shorted. Check the thermistor resistance value. The controller PCB might be defective.
  • C
    christinagraySep 12, 2025
    What to do if my Fujitsu ASYA09LCC shows discharge thermistor error?
    • T
      Theresa VargasSep 12, 2025
      If your Fujitsu Air Conditioner displays a discharge thermistor error, it means the detection value of the discharge thermistor is either open or shorted. Check the thermistor resistance value. The controller PCB might be defective.
  • E
    Elizabeth CharlesSep 12, 2025
    What does outdoor heat exchanger thermistor error mean for Fujitsu ASYA09LCC Air Conditioner?
    • F
      Felicia DavisSep 12, 2025
      If your Fujitsu Air Conditioner displays an outdoor heat exchanger thermistor error, it means the detection value of the outdoor heat exchanger thermistor is either open or shorted. Check the thermistor resistance value. The controller PCB might be defective.
  • C
    Christine GriffinSep 9, 2025
    What causes Indoor heat exchanger thermistor error in Fujitsu ASYA09LCC?
    • A
      aliciakelleySep 9, 2025
      If your Fujitsu Air Conditioner shows an indoor heat exchanger thermistor error, it means the detection value of the indoor heat exchanger thermistor is either open or shorted when the power is ON. Check the thermistor resistance value. The controller PCB might be defective.
  • D
    Donald JohnsonSep 7, 2025
    What does serial forward transfer error during the operation mean for Fujitsu ASYA09LCC Air Conditioner?
    • B
      Barbara NielsenSep 7, 2025
      If your Fujitsu Air Conditioner displays a serial forward transfer error during operation, it means the outdoor unit isn't receiving a signal for 10 seconds. Check the indoor/outdoor cable connection. If the wiring is normal, measure the voltage of the outdoor unit terminals and diagnose the defective location.
  • C
    Cassandra CarrollSep 5, 2025
    Why Fujitsu ASYA09LCC Air Conditioner shows serial forward transfer error at starting up operation?
    • J
      Joseph LeeSep 5, 2025
      If your Fujitsu Air Conditioner displays a serial forward transfer error at startup, it means the outdoor unit isn't receiving a signal for 10 seconds after the power relay turns on. Check the indoor/outdoor cable connection. If the wiring is normal, measure the voltage of the outdoor unit terminals and diagnose the defective location.
  • E
    Emily WheelerAug 20, 2025
    Why my Fujitsu Air Conditioner does not operate at all?
    • P
      Paul PenaAug 21, 2025
      If your Fujitsu Air Conditioner isn't operating, and the Operation Lamp and Timer Lamp aren't lit, you should check a few things: * Ensure the input power voltage from the exclusive circuit AC outlet is normal. * Make sure the AC plug is securely inserted into the AC outlet and isn't loose. * Verify that any connected cables are wired correctly. * Confirm that each connector is securely inserted.

Summary

Specification

ASYA07;09 LCC, AOYR07;09 LCC Specifications

Technical specifications for ASYA07/09LCC indoor and AOYR07/09LCC outdoor units.

ASYA12;14;18 LCC, AOYR12;14;18 LCC Specifications

Technical specifications for ASYA12/14/18LCC indoor and AOYR12/14/18LCC outdoor units.

ASYB09;12 LDC, AOYS09;12 LDC Specifications

Technical specifications for ASYB09/12LDC indoor and AOYS09/12LDC outdoor units.

Dimensions

ASYA07;09 LCC, AOYR07;09 LCC Dimensions

Physical dimensions for ASYA07/09LCC indoor and AOYR07/09LCC outdoor units.

ASYA12 LCC, AOYR12 LCC Dimensions

Physical dimensions for ASYA12LCC indoor and AOYR12LCC outdoor units.

ASYB09;12 LDC, AOYS09;12 LDC Dimensions

Physical dimensions for ASYB09/12LDC indoor and AOYS09/12LDC outdoor units.

ASYA14;18 LCC, AOYR14;18 LCC Dimensions

Physical dimensions for ASYA14/18LCC indoor and AOYR14/18LCC outdoor units.

Refrigerant System Diagram

ASYA07;09 LCC, AOYR07;09 LCC Diagram

Refrigerant flow diagram for ASYA07/09LCC and AOYR07/09LCC models.

ASYA12 LCC, AOYR12 LCC, ASYB09;12 LDC, AOYS09;12 LDC Diagrams

Refrigerant flow diagram for ASYA12LCC, AOYR12LCC, ASYB09/12LDC, AOYS09/12LDC.

ASYA14;18 LCC, AOYR14;18 LCC Diagrams

Refrigerant flow diagram for ASYA14/18LCC and AOYR14/18LCC models.

Circuit Diagram

ASYA07;09 LCC, AOYR07;09 LCC Diagrams

Electrical circuit diagrams for ASYA07/09LCC and AOYR07/09LCC models.

ASYA12 LCC, AOYR12 LCC Diagrams

Electrical circuit diagrams for ASYA12LCC and AOYR12LCC models.

ASYB09;12 LDC, AOYS09;12 LDC Diagrams

Electrical circuit diagrams for ASYB09/12LDC and AOYS09/12LDC models.

ASYA14;18 LCC, AOYR14;18 LCC Diagrams

Electrical circuit diagrams for ASYA14/18LCC and AOYR14/18LCC models.

Description of Each Control Operation

1. Cooling Operation

Details on how the cooling mode functions and is controlled.

2. Heating Operation

Details on how the heating mode functions and is controlled.

3. Dry Operation

Details on how the dry mode functions and is controlled.

4. Auto Changeover Operation

Explanation of automatic switching between operating modes.

5. Indoor Fan Control

How the indoor fan speed and operation are controlled.

6. Outdoor Fan Control

How the outdoor fan speed and operation are controlled.

7. Louver Control

Control of the vertical louvers and swing operation.

8. Compressor Control

Compressor operation frequency and control at start-up.

9. Timer Operation Control

Explanation of ON/OFF, Program, and Sleep timers.

10. Electronic Expansion Valve Control

Control mechanism of the electronic expansion valve.

11. Test Operation Control

Procedure for performing test operation of the unit.

12. Prevent to Restart for 3 Minutes

Mechanism to prevent immediate restart after shutdown.

13. Four-Way Valve Extension Select

Function related to the four-way valve switching.

14. Auto Restart

How the unit restarts after a power interruption.

15. Manual Auto Operation

Operation controlled via the indoor unit body.

16. Forced Cooling Operation

Procedure for initiating forced cooling mode.

17. Compressor Preheating

Function to preheat the compressor before operation.

18. Coil Dry or Air Clean Operation Control

Control for coil dry and air cleaning functions.

19. Defrost Operation Control

Conditions and process for defrost operation.

20. Off Defrost Operation Control

Conditions and process for off-cycle defrost operation.

21. Various Protections

Overview of various protection mechanisms and controls.

Refrigerant Caution -R410 A

R410 A Tools and Equipment

Necessary tools and equipment for handling R410A refrigerant.

Precaution for Installation

Important safety and procedural precautions during installation.

Precaution for Servicing

Safety and procedural precautions during servicing operations.

New Refrigerant R410 A Information

Details about R410A refrigerant and its properties.

Differences from Conventional Model (R22) and Precautions

Key differences between R410A and R22 models and related precautions.

Trouble Shooting

Unit Does Not Operate

Troubleshooting steps when the unit fails to start.

Self-Diagnosis Function

How to use and interpret the unit's self-diagnosis system.

Serial Signal Diagnosis

Procedure for diagnosing issues via serial signal communication.

IPM Protection

Troubleshooting steps for IPM protection errors.

Refrigerant Cycle Troubleshooting

Methods for diagnosing problems within the refrigerant cycle.

Appending Data

Jumper Setting

Configuration settings using jumper pins for indoor and outdoor units.

Pressure and Current Curves

Graphs showing pressure and current values under various conditions.

Thermistor Resistance Values

Table of thermistor resistance values at different temperatures.

Capacity;Input Data

Data charts illustrating unit capacity and input power.

Replacement Parts

ASYA07;09 LCC & AOYR07;09 LCC Parts

Exploded views of replacement parts for ASYA07/09LCC and AOYR07/09LCC.

ASYA12 LCC & AOYR12 LCC Parts

Exploded views of replacement parts for ASYA12LCC and AOYR12LCC.

ASYA14;18 LCC & AOYR14;18 LCC Parts

Exploded views of replacement parts for ASYA14/18LCC and AOYR14/18LCC.

ASYB09;12 LDC & AOYS09;12 LDC Parts

Exploded views of replacement parts for ASYB09/12LDC and AOYS09/12LDC.

Wiring and Assembly Processes

Diagrams illustrating wiring and assembly procedures for components.

Installation Manual

General Installation Instructions and Warnings

Key guidelines, warnings, and requirements for unit installation.

Standard Accessories

List and description of standard parts supplied with the unit.

Electrical Requirements

Specifications and precautions for the unit's electrical connection.

Mounting Position Selection

Guidelines for choosing optimal indoor and outdoor unit locations.

Installation Diagrams

Visual representations of unit placement and clearances.

Panel and Grille Removal;Installation

Procedures for removing and installing unit panels and grilles.

Pump Down Operation (Forced Cooling)

Method for recovering refrigerant during unit relocation or disposal.

Refrigerant and Piping Precautions

Important safety measures for handling refrigerant and piping.

Special Tools for R410 A

List of specialized tools required for R410A systems.

Copper Pipe Specifications

Recommended copper pipe materials, dimensions, and thickness.

Piping and Flare Nut Tightening

Procedures and torque specifications for connecting refrigerant pipes.

Indoor Unit Wiring

Instructions for correctly wiring the indoor unit.

Outdoor Unit Installation and Air Purge

Steps for installing the outdoor unit and purging air from the system.

Finishing and Test Running

Final checks, insulation, and procedures for test operation.

Fujitsu ASYA09LCC Specifications