EasyManua.ls Logo

Fujitsu ASYA09LGC - Specifications: ASYA09 LGC;AOYR09 LGC & ASYA12 LGC;AOYR12 LGC; Model Type and Capacity; Electrical Data; Compressor Specifications

Fujitsu ASYA09LGC
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SPECIFICATIONS
TYPE
Cool & heat inverter
INDOOR UNIT
ASYA12LGC
OUTDOOR UNIT
AOYR12LGC
COOLING CAPACITY
3.40 kW
HEATING CAPACITY
4.00 kW
POWER SOURCE
230 V
FREQUENCY
50 Hz
RUNNING
CURRENT
MAXIMUM CURRENT
4.3 A
4.6 A
INPUT WATTS
0.895 kW
0.970 kW
E.E.R.
Cooling
3.80 kW/kW
COP
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
4.12 kW/kW
MOISTURE REMOVAL
1.8 L/h
AIR CIRCULATION
HIGH
750 m
3
/h
750 m
3
/h
ASYA09LGC
AOYR09LGC
2.50 kW
3.20 kW
230 V
50 Hz
3.2 A
3.7 A
6.5 A
9.0 A
6.0 A
7.5 A
0.630 kW
0.750 kW
3.97 kW/kW
4.27 kW/kW
1.3 L/h
750 m
3
/h
750 m
3
/h
FAN MOTOR
COMPRESSOR TYPE
Hermetic type,
4 pole, 3 phase,
DC inverter motor, Rotary
DISCRIMINATION
DA89X1C-20FZ
5SS072XAA
STANDARD REFRIGERANT
REFRIGERANT TYPE
R410AR410A
800 g
800 g
650 g
650 g
WEIGHT (with oil)
9.9 kg5.9 kg
POWER SOURCE
230 V
High speed
INDOOR UNIT
Middle speed
Low speed
Quiet
High speed
Middle speed
Low speed
Quiet
Cool 1,440 r.p.m. / Heat 1,440 r.p.m.
Cool 1,200 r.p.m. / Heat 1,200 r.p.m.
Cool 920 r.p.m. / Heat 980 r.p.m.
Cool 680 r.p.m. / Heat 700 r.p.m.
OUTDOOR UNIT
? r.p.m.
ELECTRICAL DATA
COMPRESSOR AND REFRIGERANT
Pipe Length
15 m
FULL CHARGE
20 m
900 g750 g
MAXIMUM PIPING HEIGHT
15m
ADDITIONAL REFRIGERANT
20 g/m
INDOOR UNIT
OUTDOOR UNIT
WEIGHT
INDOOR UNIT
Gross / Net
Gross / Net
10 kg / 7.5 kg
OUTDOOR UNIT
35 kg / 32 kg28 kg / 25 kg
NOISE LEVEL
Cool 43 dB / Heat 43 dB
Cool 38 dB / Heat 38 dB
Cool 33 dB / Heat 33 dB
Cool 21 dB / Heat 21 dB
C 45 dB / H 45 dB
C 48 dB / H 48 dB
INDOOR UNIT
H x W x D
H x W x D
260 x 790 x 198 mm
OUTDOOR UNIT
540 x 660 x 290 mm
DIMENSIONS
2008.01.07 1