Fujitsu ASYA12LGC - Service Manual

Fujitsu ASYA12LGC
140 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
SERVICEMANUAL
INVERTER
ASYA07LCC
ASYA09LCC
ARCTIC 7LCC
ARCTIC 9LCC
ASYA12LCC
ARCTIC 12LCC
ASYA14LCC
ASYA18LCC
ARCTIC 14LCC
ASYA09LGC
ASYA12LGC
ARCTIC 9LGC
ARCTIC 12LGC
ASYA14LGC
ARCTIC 14LGC
ASYB09LDC
ASYB12LDC
ASYB18LDC
AGYV09LAC
AGYV12LAC
AGYV14LAC
AWYZ14LBC
AWYZ18LBC
AWYZ24LBC
V2-2009
ASY9LSACW
ASY12LSACW
ASY9LSACW
ASY12LSACW
ASY9LSBCW
ASY12LSBCW
Feilkoder
alle modeller
Utvidet feilsøkings-
rutiner på Fujitsu
Inverter utedeler
Tips til montøren

Other manuals for Fujitsu ASYA12LGC

Questions and Answers

  • K
    Kenneth PetersAug 17, 2025
    What to do if my Fujitsu Air Conditioner shows an IPM protection error?
    • D
      David CoxAug 18, 2025
      If your Fujitsu Air Conditioner displays an IPM protection error, it could be due to the following reasons: * Blocked heat radiation (inlet/outlet): Ensure that there are no obstructions blocking the inlet or outlet. * Defective outdoor fan: Check if the outdoor fan is working correctly and rotating properly. * Open valves: Verify that the 2-way or 3-way valve is not left open. * Compressor issues: Inspect the compressor's winding resistance value and check for any loose lead wires.
  • H
    heather66Aug 20, 2025
    What to do if my Fujitsu Air Conditioner has a compressor location error?
    • C
      Christina DavidsonAug 20, 2025
      If your Fujitsu Air Conditioner is showing a compressor location error, check the following: * Valves: Ensure that the 2-way or 3-way valve is not left open. * Compressor: Inspect the compressor's winding resistance value and check for any loose lead wires.
  • G
    Gloria HatfieldAug 23, 2025
    What to do if my Fujitsu Air Conditioner shows a wired remote controller error?
    • E
      Erin RamirezAug 23, 2025
      If your Fujitsu Air Conditioner is showing a wired remote controller error, check the wiring. It may also indicate a Controller PCB failure.
  • J
    Julia CooperAug 25, 2025
    How to troubleshoot a room temperature thermistor defect in Fujitsu ASYA12LGC?
    • J
      John ThompsonAug 26, 2025
      To troubleshoot a defective room temperature thermistor in your Fujitsu Air Conditioner, check the thermistor resistance value. Refer to the "Thermistor characteristics table" for the correct values.
  • J
    Jacqueline FosterAug 27, 2025
    How to troubleshoot an indoor heat exchanger thermistor error in Fujitsu ASYA12LGC?
    • J
      Julie FullerAug 27, 2025
      To troubleshoot an indoor heat exchanger thermistor error in your Fujitsu Air Conditioner, check the thermistor resistance value. Refer to the "Thermistor characteristic table" for the correct values.
  • V
    valenzuelakristiAug 30, 2025
    How to troubleshoot a discharge thermistor error in Fujitsu ASYA12LGC Air Conditioner?
    • M
      Ms. Lauren Mckenzie DVMAug 30, 2025
      To troubleshoot a discharge thermistor error in your Fujitsu Air Conditioner, check the thermistor resistance value. Refer to the "Thermistor characteristics table".
  • M
    Michelle RossSep 1, 2025
    How to troubleshoot an outdoor heat exchanger thermistor error in Fujitsu ASYA12LGC Air Conditioner?
    • R
      rgonzalezSep 2, 2025
      To troubleshoot an outdoor heat exchanger thermistor error in your Fujitsu Air Conditioner, check the thermistor resistance value. Refer to the "Thermistor characteristics table".
  • E
    edward95Sep 4, 2025
    How to troubleshoot an outdoor temperature thermistor error in Fujitsu ASYA12LGC Air Conditioner?
    • A
      andrewlarsonSep 4, 2025
      To troubleshoot an outdoor temperature thermistor error in your Fujitsu Air Conditioner, check the thermistor resistance value. Refer to the "Thermistor characteristics table".
  • E
    Emily ShepherdSep 6, 2025
    What causes a forced auto switch error in Fujitsu ASYA12LGC?
    • S
      Susan AllenSep 7, 2025
      If you're getting a forced auto switch error on your Fujitsu Air Conditioner, check if the forced auto switch is being kept pressed.
  • P
    Paul JohnsonSep 9, 2025
    What to do if my Fujitsu ASYA12LGC Air Conditioner shows a main relay error?
    • P
      Patricia AndersonSep 9, 2025
      If your Fujitsu Air Conditioner is showing a main relay error, it likely indicates that the main relay is defective.

Summary

Feilkoder og Feilsøkning

Feilkoder for Classic Series

Error codes and troubleshooting for Classic models.

Feilkoder for Gulvmodell AGYV Series

Error codes and troubleshooting for AGYV floor models.

Utvidet Feilsøkingsrutiner for Inverter Utedeler

Detailed troubleshooting for inverter outdoor units.

Inverter Feil Analyse

Analyse av Diodebro

Step-by-step analysis of the diode bridge.

Analyse av Aktivt Filtermodul

Analysis and testing of the active filter module.

Analyse av IPM Module

Component and operational tests for the IPM module.

Tekniske Data og Diagrammer

Spesifikasjoner for ASY9;12 LSACW

Technical specifications for ASY9/12LSACW models.

Circuit Diagram for ASY9;12 LSACW

Wiring diagrams for ASY9/12LSACW indoor/outdoor units.

Refrigerant System Diagram

Diagram illustrating refrigerant flow and components.

Installasjon og Vedlikehold

Gjennomgang av Monteringen

Step-by-step installation overview.

Vakuumering og Klargjøring

Procedure for connecting gauges and vacuuming.

Trykktesting med Nitrogen

Steps for performing nitrogen pressure testing.

Fujitsu ASYA12LGC Specifications

General IconGeneral
TypeSplit System
Cooling Capacity3.4 kW
Heating Capacity4.0 kW
Energy Efficiency Ratio (EER)3.21
RefrigerantR410A
Weight (Indoor Unit)9 kg
Power Input (Cooling)1060 W
Power Input (Heating)1110 W
Noise Level (Indoor)43 dB(A)
Air Flow (Indoor)700 m3/h