SERVICEMANUAL
INVERTER
ASYA07LCC
ASYA09LCC
ARCTIC 7LCC
ARCTIC 9LCC
ASYA12LCC
ARCTIC 12LCC
ASYA14LCC
ASYA18LCC
ARCTIC 14LCC
ASYA09LGC
ASYA12LGC
ARCTIC 9LGC
ARCTIC 12LGC
ASYA14LGC
ARCTIC 14LGC
ASYB09LDC
ASYB12LDC
ASYB18LDC
AGYV09LAC
AGYV12LAC
AGYV14LAC
AWYZ14LBC
AWYZ18LBC
AWYZ24LBC
V2-2009
ASY9LSACW
ASY12LSACW
ASY9LSACW
ASY12LSACW
ASY9LSBCW
ASY12LSBCW
Feilkoder
alle modeller
Utvidet feilsøkings-
rutiner på Fujitsu
Inverter utedeler
Tips til montøren

Other manuals for Fujitsu ASYA18LCC

Questions and Answers

  • K
    kevinjonesSep 4, 2025
    What does serial reverse transfer error during the operation mean for Fujitsu ASYA18LCC Air Conditioner?
    • S
      Stacey AndersonSep 4, 2025
      If your Fujitsu Air Conditioner displays a serial reverse transfer error during operation, it means the indoor unit isn't receiving a signal for 10 seconds. Check the indoor/outdoor cable connection. If the wiring is normal, measure the voltage of the outdoor unit terminals and diagnose the defective location.
  • T
    Terry ArmstrongSep 18, 2025
    Why Fujitsu ASYA18LCC has power supply frequency detection error?
    • K
      kelseyyoderSep 18, 2025
      If your Fujitsu Air Conditioner displays a power supply frequency detection error, it means the power supply frequency cannot be recognized after 4 seconds of power ON. The Controller PCB might be defective.
  • W
    Willie CampbellSep 16, 2025
    What does forced auto switch error mean on Fujitsu Air Conditioner?
    • C
      Christopher RobbinsSep 16, 2025
      If your Fujitsu Air Conditioner displays a forced auto switch error, it means the forced auto switch has been ON for 30 consecutive seconds. Check if the forced auto switch is kept pressed. The forced auto switch might be defective or the Controller PCB might be defective.
  • P
    Paul AndersonSep 14, 2025
    What to do if my Fujitsu Air Conditioner shows outdoor temperature thermistor error?
    • J
      Joseph MortonSep 14, 2025
      If your Fujitsu Air Conditioner displays an outdoor temperature thermistor error, it means the detection value of the outdoor temperature thermistor is either open or shorted. Check the thermistor resistance value. The controller PCB might be defective.
  • T
    Tanner MccallSep 13, 2025
    What does outdoor heat exchanger thermistor error mean for Fujitsu ASYA18LCC?
    • M
      mary43Sep 13, 2025
      If your Fujitsu Air Conditioner displays an outdoor heat exchanger thermistor error, it means the detection value of the outdoor heat exchanger thermistor is either open or shorted. Check the thermistor resistance value. The controller PCB might be defective.
  • A
    Angel GriffithSep 12, 2025
    What to do if my Fujitsu ASYA18LCC Air Conditioner shows discharge thermistor error?
    • D
      Derrick PowellSep 12, 2025
      If your Fujitsu Air Conditioner displays a discharge thermistor error, it means the detection value of the discharge thermistor is either open or shorted. Check the thermistor resistance value. The controller PCB might be defective.
  • M
    maria91Sep 9, 2025
    What causes Indoor heat exchanger thermistor error in Fujitsu ASYA18LCC Air Conditioner?
    • J
      julia89Sep 9, 2025
      If your Fujitsu Air Conditioner shows an indoor heat exchanger thermistor error, it means the detection value of the indoor heat exchanger thermistor is either open or shorted when the power is ON. Check the thermistor resistance value. The controller PCB might be defective.
  • K
    Kevin SalazarSep 7, 2025
    What does serial forward transfer error during the operation mean for Fujitsu ASYA18LCC?
    • M
      Margaret MoranSep 7, 2025
      If your Fujitsu Air Conditioner displays a serial forward transfer error during operation, it means the outdoor unit isn't receiving a signal for 10 seconds. Check the indoor/outdoor cable connection. If the wiring is normal, measure the voltage of the outdoor unit terminals and diagnose the defective location.
  • K
    Katie MartinSep 5, 2025
    Why Fujitsu Air Conditioner shows serial forward transfer error at starting up operation?
    • G
      gonzalezanthonySep 5, 2025
      If your Fujitsu Air Conditioner displays a serial forward transfer error at startup, it means the outdoor unit isn't receiving a signal for 10 seconds after the power relay turns on. Check the indoor/outdoor cable connection. If the wiring is normal, measure the voltage of the outdoor unit terminals and diagnose the defective location.
  • H
    hernandezwilliamAug 21, 2025
    Why my Fujitsu Air Conditioner does not operate at all?
    • B
      Brittany GarciaAug 21, 2025
      If your Fujitsu Air Conditioner isn't operating, and the Operation Lamp and Timer Lamp aren't lit, you should check a few things: * Ensure the input power voltage from the exclusive circuit AC outlet is normal. * Make sure the AC plug is securely inserted into the AC outlet and isn't loose. * Verify that any connected cables are wired correctly. * Confirm that each connector is securely inserted.

Summary

Fujitsu Air Conditioner Error Codes

FEILKODER for Fujitsu Luft til Luft Varmepumper

General error codes for Fujitsu air-to-air heat pumps.

FEILKODER CLASSIC ASY9-12 LSACW

Error codes and diagnostics for Classic ASY9-12LSACW models.

FEILKODER CLASSIC ASY9-12 LSBCW

Error codes and diagnostics for Classic ASY9-12LSBCW models.

FEILKODER CLASSIC ASYA07-18 LCC

Error codes and diagnostics for Classic ASYA07-18LCC models.

FEILKODER PLASMA ASYB09-24 LDC

Error codes and diagnostics for Plasma ASYB09-24LDC models.

FEILKODER GULVMODELL AGYV09-14 LAC

Error codes and diagnostics for Floor models AGYV09-14LAC.

FEILKODER NOCRIA AWYZ14-18 LBC

Error codes and diagnostics for NO CRIA AWYZ14-18LBC models.

Fujitsu Inverter Outdoor Unit Troubleshooting

Utvidet feilsøkingsrutiner på Fujitsu Inverter utedeler

Advanced troubleshooting procedures for Fujitsu Inverter outdoor units.

10 Punkts Plan m; Inverter sjekker

A 10-point plan for checking Fujitsu inverter outdoor units.

Installation and Refrigerant Handling Procedures

Gjennomgang av monteringen

A step-by-step guide for mounting indoor and outdoor units.

Rørgjennonføring i trevegg

Guide for routing pipes through a wooden wall.

Kople manometer til utedelen på varmepumpen og vakuumere

Instructions for connecting a manifold gauge and vacuuming the system.

VANNETS KOKEPUNKT VED SKIFTENDE TRYKK

Table showing water boiling points at different pressures (vacuum).

ETTERFYLLING AV GASS R410 A OG R407 C MED MANOMETER MED 2 RATT

Procedure for refilling R410A and R407C gas using a 2-gauge manifold.

Ta gassen tilbake til anlegget

Procedure for recovering refrigerant gas back into the system.

Inverter Fault Analysis

Pump Down for små modeller

How to activate Auto Pump Down function on small models.

Pump Down for store modeller

How to activate Auto Pump Down function on large models.

Tømming og refylling av anlegg

Procedure for emptying and refilling the refrigeration system.

Trykktesting med Nitrogen

Leak testing the system using nitrogen gas.

Fujitsu ASYA18LCC Specifications

General IconGeneral
RefrigerantR410A
Weight (Indoor Unit)11.5 kg
Weight (Outdoor Unit)41 kg
TypeSplit
Energy Efficiency Ratio (EER)3.5
Power Supply220-240 V, 50 Hz