ASYA09LCC Capacity/Input data
(1/2)
< Capacity >
<Input>
*Defrosting operation is performed when temperature is less than 5.5 degrees C.
Frost appears on an outdoor unit heat exchanger at 5.5 or less degrees C.
*Solid line:Integral capacity/Input containing the defrosting cycle.
*Dotted line:Capacity/Input which does not contain the defrosting cycle.
Heating
40%
50%
60%
70%
80%
90%
100%
110%
120%
130%
140%
150%
160%
170%
180%
-15 -10 -5 0 5 10 15 20 25
Capacity(%)
70%
80%
90%
100%
110%
120%
130%
140%
150%
160%
170%
180%
190%
200%
210%
220%
-15 -10 -5 0 5 10 15 20 25
Input(%)
Rated
operation
24
24
Maximum
operation
5.5
5.5
Rated
operation
n
Maximum
operation
Without Frost
Without Frost
With Frost
Without Frost
With Frost
Without Frost
IndoorDB:20 C
Outdoor DB( C)
Outdoor DB( C)
IndoorDB:20 C
08-09