EasyManua.ls Logo

Fujitsu ASYG07-14KGTF - Swing Operation

Fujitsu ASYG07-14KGTF
482 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-6. Swing operation
¢ Compact cassette type
To select up/down airflow swing operation
When the swing signal is received, the horizontal louver starts to swing.
Swinging range
Cooling mode/dry mode/fan mode: 1 ↔ 4
Heating mode: 1 ↔ 4
When the indoor fan is S-LOW or stop mode, the swing operation is interrupted and it stops at
either upper end or bottom end.
¢ Wall mounted type
To select up/down airflow swing operation
When the swing signal is received, the horizontal louver starts to swing.
Swinging range
Cooling mode/dry mode/fan mode (1 to 3): 1 ↔ 4
Heating mode/fan mode (4 to 6): 3 ↔ 6
When the indoor fan is S-LOW or stop mode, the swing operation is interrupted and it stops at
either upper end or bottom end.
To select left/right airflow swing operation (for KMTB model only)
When the swing signal is received, the vertical louver starts to swing.
Swinging range
All mode: 1 ↔ 5
When the indoor fan is S-LOW or stop mode, the swing operation is interrupted and it stops at
either left end or right end.
To select up/down and left/right airflow swing operation (for KMTB model only)
When the swing signal is received, the horizontal and the vertical louvers start to swing.
¢ Ceiling type
To select up/down airflow swing operation
When the swing signal is received, the horizontal louver starts to swing.
Swinging range
Cooling mode/dry mode/fan mode: 1 ↔ 7
Heating mode: 1 ↔ 7
When the indoor fan is S-LOW or stop mode, the swing operation is interrupted and it stops at
either upper end or bottom end.
¢
Floor type
To select up/down airflow swing operation
When the swing signal is received, the horizontal louver starts to swing.
Swinging range
Cooling mode/dry mode/fan mode: 1 ↔ 5
Heating mode: 1 ↔ 5
When the indoor fan is S-LOW or stop mode, the swing operation is interrupted and it stops at
either upper end or bottom end.
4-6. Swing operation