AIR CONDITIONER
3-unit multi-split type
SERVICE MANUAL
INDOOR
AUXG07–18KVLA ARXG07–14KSLAP
ARXG18KSLAP
ARXG07–14KLLAP
ARXG18KLLAP
ASYG07–14KGTB
ASYG07–14KGTE
ASYG07–14KGTF
ASYG18KMTB
ASYG18KMTE
ASYG07–14KMTB
ASYG07–14KMCC
ASYG07–14KMCE
ASYG07–14KMCF
ASYG07–14KETA
ASYG07–14KETE
ASYG07–14KETF
ASYG07–14KETA-B
ASYG07–14KETE-B
ASYG07–14KETF-B
OUTDOOR
ABYG18KRTA AGYG09–14KVCA AOYG18KBTA3
AOYG24KBTA3
SR_MU003EF_14
2023.03.17

Table of Contents

Questions and Answers:

Fujitsu ASYG07-14KGTF Specifications

General IconGeneral
BrandFujitsu
ModelASYG07-14KGTF
CategoryAir Conditioner
LanguageEnglish

Summary

1. GENERAL INFORMATION

1. Specifications

Details specifications for indoor and outdoor units, including capacity, power, airflow, sound pressure, dimensions, etc.

2. Dimensions

Provides detailed installation dimensions and space requirements for various indoor unit types.

1. Precautions

Service personnel

Requirements for service personnel, including certifications and competence in handling refrigerants.

Work

Guidelines for safe work practices, including electrical safety and handling of flammable refrigerants.

Checking for presence of refrigerant

Procedures for checking for refrigerant leaks using appropriate detectors.

2. Cassette grille (optional part) parts list

2-1. Model: UTG-UFYF-W

Exploded view and part numbers for the UTG-UFYF-W cassette grille.

3. Indoor unit parts list

3-1. Compact cassette type

Lists components of the compact cassette indoor unit, including drain hose, hose band, and thermistors.

3. TROUBLESHOOTING

1. Error code

Explains how to check and erase error memory, and provides a table of indoor/outdoor unit error codes.

2. Troubleshooting with error code

Provides step-by-step troubleshooting procedures for various error codes related to indoor and outdoor units.

4. CONTROL AND FUNCTIONS

1. Rotation number control of compressor

Explains how compressor rotation is controlled based on room temperature, outdoor temperature, and operation modes.

2. Auto changeover operation

Explains the auto changeover function based on room temperature and outdoor unit status.

5. FILED WORKING

1. Function settings (for indoor unit)

Details how to set functions for various indoor unit types using DIP switches and remote controllers.

2. Function settings (for outdoor unit)

Explains how to adjust DIP switches and push switches on the outdoor unit control board for various settings.

3. Check and test

3-1. Check run

Instructions on performing a check run to screen and detect wiring errors, and automatic wiring correction.

3-2. Test run

Step-by-step guide for performing a test run on the air conditioner, including pre-checks and operation.