EasyManua.ls Logo

Fujitsu ASYG09LLCE - Service Manual

Fujitsu ASYG09LLCE
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
SPLIT TYPE
ROOM AIR CONDITIONER
WALL MOUNTED
type
INVERTER
SERVICE
INSTRUCTION
R410A
Models Indoor unit Outdoor unit
AS*G07LLCC
AS*G09LLCC
AS*G12LLCC
AO*G07LLCC
AO*G09LLCC
AO*G12LLCC
AS*G07LLCD
AS*G09LLCD
AS*G12LLCD
AO*G07LLCD
AO*G09LLCD
AO*G12LLCD
RSG07LLCC
RSG09LLCC
RSG12LLCC
ROG07LLCC
ROG09LLCC
ROG12LLCC
ASYG07LLCE
ASYG09LLCE
ASYG12LLCE
AOYG07LLCE
AOYG09LLCE
AOYG12LLCE
ASYG07LLCE-R
ASYG09LLCE-R
ASYG12LLCE-R
AOYG07LLCE-R
AOYG09LLCE-R
AOYG12LLCE-R

Other manuals for Fujitsu ASYG09LLCE

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASYG09LLCE and is the answer not in the manual?

Fujitsu ASYG09LLCE Specifications

General IconGeneral
TypeAir conditioner indoor unit
Multi-split-
Product colorWhite
Inverter technologyYes
Refrigerating mediumR410A
Air conditioner functionsCooling, Dehumidifying, Heating
Refrigerating medium weight650 g
Cooling capacity in watts (nominal)- W
Operating temperature (cooling) (T-T)-10 - 43 °C
Operating temperature (heating) (T-T)-15 - 24 °C
Heating capacity in watts (nominal) (Average heating season)3000 W
Airflow1670 m³/h
Outdoor unit noise level- dB
AC input voltage230 V
AC input frequency50 Hz
Design load (cooling)- kW
Annual energy consumption (cooling)127 kWh
Hourly energy consumption (cooling)- kWh
Indoor unit typeWall-mountable
Indoor unit depth206 mm
Indoor unit width820 mm
Indoor unit height262 mm
Indoor unit weight7000 g
Indoor unit noise level (high speed)720 dB

Summary

Description of Control Operations

Cooling Operation

Explains how the compressor frequency is controlled based on room temperature.

Heating Operation

Details compressor frequency control based on room temperature for heating.

Compressor Control

Defrost Operation Control

Defrost Operation Start Conditions

Specifies conditions for initiating defrost operation.

Defrost Operation Completion Conditions

Outlines conditions for ending defrost operation.

Off Defrost Operation Control

Various Protections

Discharge Gas Temperature Prevention

Prevents compressor damage from high discharge gas temperature.

Antifreezing Control

Prevents indoor heat exchanger from freezing in cooling/dry modes.

Cooling Pressure Overrise Protection

Stops unit if outdoor heat exchange sensor temperature is too high.

Trouble Shooting

Error Display

Lists error codes and corresponding flashing patterns for indoor units.

Troubleshooting with Error Codes

Provides step-by-step troubleshooting for specific error codes.

Troubleshooting with No Error Codes

Guides for diagnosing issues with no error display.

Indoor Unit No Power Troubleshooting

Diagnoses issues related to the indoor unit having no power.

Outdoor Unit No Power Troubleshooting

Diagnoses issues related to the outdoor unit having no power.

No Operation (Power ON) Troubleshooting

Guides for diagnosing when the unit is on but not operating.

No Cooling; No Heating Troubleshooting

Diagnoses issues when the unit doesn't cool or heat.

Service Parts Information

Compressor Service Information

Guides for diagnosing and replacing the compressor.