6. SYSTEM DESIGN
ERROR STATUS OUTPUT

Compact
Cassette
Slim Duct
Wall Mounted
Floor /
Ceiling
Floor
LJ LU / LM LF
Connector
- - -
CNB02
- - -
An air conditioner error status signal can be output.
Circuit diagram example

*1 PC board of Communication kit is used for Wall mounted type..
*2 Make the distance from the PC board to the connected unit within 10 m.
Relay spec.: Max. DC 24 V, 10 mA to less than 500 mA.

Parts (Optional)

Compact
Cassette
Slim Duct
Wall Mounted
Floor /
Ceiling
Floor
LJ LU / LM LF
Parts name - - - External connect kit - - -
Model name - - - UTY-XWZXZ5 - - -
Compact
Cassette
Slim Duct
Wall Mounted
Floor /
Ceiling
Floor
LJ LU LM LF
Parts name - - - Communication kit - - -
Model name - - - UTY-T WBXF UT Y-XCBXZ2 - - -
*For operating the EXTERNAL OUTPUT function, the Wall mounted type (LU, LM) requires the communication kit
(UTY-TWBXF, UTY-XCBXZ2) in addition to the wire (UTY-XWZXZ5).