EasyManuals Logo

Fujitsu AUXB07GALH User Manual

Fujitsu AUXB07GALH
255 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #152 background imageLoading...
Page #152 background image
Error Contents :
The abnormality in connection
of remote controller cable
Symptom :
LED repeats flashing 0.5sec ON & 0.5sec OFF.
Condition :
Communication with Indoor unit has been cut off for longer than 1 minute.
OK
Cause 4 : External noise
OK
Cause 5 : Ext. Switch Controller is defective.
Replace External Switch Controller.
OK
Cause 1 :
Communication cable is defective or open.
Check installation of connection cable.
Check if connection cable is open.
Cause 2 : Defective insertion or open
connection of the cable between External
Switch Controller terminal and PCB.
Check connector insertion.
Check if connection cable is open.
Cause 3 : DIP switch setting defective
Check setting of DIP-SW1-4, 1-5, 1-6.
OK
Remove or shut out external noise source.
Trouble shooting 74
04-82

Table of Contents

Other manuals for Fujitsu AUXB07GALH

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AUXB07GALH and is the answer not in the manual?

Fujitsu AUXB07GALH Specifications

General IconGeneral
BrandFujitsu
ModelAUXB07GALH
CategoryAir Conditioner
LanguageEnglish

Related product manuals