SERVICE PARTS INFORMATION 5
IPM
(Mounted on Inverter PCB)
Check Point 1
Check Point 2
Terminal U
Terminal V
Terminal W
Terminal U
Terminal V
Terminal W
Disconnect the connection wires between the Inverter
PCB - ACTPM and Inverter PCB - Inverter Compressor.
Set the tester to the "Resistance" mode, and measure
the resistance between the following terminals.
P - Terminals U / V / W
N (TM482) - Terminals U / V / W
Set the tester to the "Diode" mode, and measure the voltage value between the following terminals.
Judge the result of as follows:
All 6 points several M or greater : Normal
1 or more points several k to short : Defective
All 6 points several 0.3V to 0.7V : Normal
1 or more points under 0.1V or over load : Defective
Judge the result of as follows:
Tester +side
(red)
Tester - side
(black)
Tester display
[V]
(P)
(N)