06-13
Procedure for compressor installation.
Reverse procedure to removing the compressor.
Precautions for installation of Compressor.
(1) When brazing, do not apply the flame to the terminal.
(2) When brazing, be sure to replace the air in the pipe with nitrogen gas to prevent forming oxidization scale.
Thermistor (Discharge)
HEATER (CRANK CASE)
Discharge side
Cut the binders. (2 place) Remove the Thermistor clip and
Thermistor(Discharge).
Remove the HEATER.
(CRANK CASE)
Remove the COMP BOLTs.
(4 places)
Heat up the brazed part of
the discharge side and disconnect.
Heat up the brazed part of the suction side and disconnect.
Remove the COMPRESSOR.
Suction side
Caution
There is a possibility of catching fire to oil when removing by the welding.
Thermistor (Comp.temp.)
HEATER (CRANK CASE)
Thermistor (Discharge)
Thermistor (Comp.temp.)
Remove the Thermistor
(Comp.temp)
Hook