3. Fan control
Tr: Room temperature
Ts: Setting temperature
3-1. Indoor fan control
¢ Fan speed
Indoor fan speed is defined as below.
Operation mode Fan mode
Speed (rpm)
ARXG09KLLAP ARXG12KLLAP ARXG14KLLAP ARXG18KLLAP
Heating
HIGH 1,260 1,340 1,560 1,380
MED 1,160 1,240 1,400 1,300
LOW 1,060 1,140 1,240 1,220
QUIET 960 1,030 1,030 1,140
S-LOW 500 500 500 600
Cooling/Fan
HIGH 1,260 1,340 1,560 1,380
MED 1,160 1,240 1,400 1,300
LOW 1,060 1,140 1,240 1,220
QUIET 960 1,030 1,030 1,140
Soft quiet
500*
1
500*
1
500*
1
600*
1
S-LOW
500*
2
500*
2
500*
2
600*
2
Dry
X zone: 960
J zone: 960
X zone: 1,030
J zone: 1,030
X zone: 1,030
J zone: 1,030
X zone: 1,140
J zone: 1,140
*1: Fan mode only
*2: Cooling mode only
¢ Fan operation
Airflow can be switched in 5 steps such as AUTO, QUIET, LOW, MED, HIGH while indoor unit fan
only runs.
When fan mode is set at AUTO, it operates on MED fan speed.
¢ Cooling operation
Switch the airflow AUTO, and indoor fan motor will run according to room temperature, as below.
On the other hand, if switched in HIGH—QUIET, indoor motor will run at a constant airflow of COOL
operation modes QUIET, LOW, MED, HIGH as shown in “Fan speed” above.
Airflow change over (Cooling: Auto)
¢
Dry operation
During dry operation, fan speed setting can not be changed as shown in “Fan speed” above.
3-1. Indoor fan control
- (01-10) - 3. Fan control
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS

Other manuals for Fujitsu AUXG09KVLA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AUXG09KVLA and is the answer not in the manual?

Fujitsu AUXG09KVLA Specifications

General IconGeneral
BrandFujitsu
ModelAUXG09KVLA
CategoryAir Conditioner
LanguageEnglish

Related product manuals