3. Fan control
Tr: Room temperature
Ts: Setting temperature
3-1. Indoor fan control
¢ Fan speed
Indoor fan speed is defined as below.
Operation mode Fan mode
Speed (rpm)
ASHG07KPCE
ASHG09KPCE
ASHG12KPCE
Heating
POWERFUL 1,370 1,470
HIGH 1,300 1,400
MED+ 1,190 1,280
MED 1,080 1,140
LOW 930 930
QUIET 700 700
Cool air prevention 630 630
S-LOW 580 580
Cooling/Fan
POWERFUL 1,370 1,470
HIGH 1,300 1,400
MED 1,080 1,140
LOW 850 890
QUIET 650 630
Soft quiet
580*
1
580*
1
S-LOW
580*
2
580*
2
Dry
X zone: 650
J zone: 650
X zone: 650
J zone: 650
*1: Fan mode only
*2: Cooling mode only
¢ Fan operation
Airflow can be switched in 5 steps such as AUTO, QUIET, LOW, MED, HIGH while indoor unit fan
only runs.
When fan mode is set at AUTO, it operates on MED fan speed.
3-1. Indoor fan control
- (04-8) - 3. Fan control
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS

Related product manuals