*1: By applying Internal HDD Unit Bay Conversion kit (PG-BC102), 5 inch bay x 2 can be converted to 3.5 inch x 3.
*2: Frequency will be changed by the spec of PCI card and number of cards mounted.
*Components installed as standard configuration marked in grey.
Remote Service Board PG-RSB103 1
RAID Ctrl 0-Channel 128MB PG-140D1 PCI-X/64bit Internal array
RAID Ctrl 2-Channel 128MB w/BBU
PG-142E3 PCI/64bit Internal array/External array
SCSI Ctrl U160 PG-128 PCI/64bit
Internal / External SCSI Controller
Fibre Channel Controller PG-FC107 PCI-X/64bit
Eth. Ctrl 1000-BASE-T Cu PG-1892 PCI-X/64bit
Eth. Ctrl 1000-BASE-SX Fibre LC PG-1882 PCI-X/64bit
Eth. Ctrl 1000-BASE-T Cu PG-1852 PCI/32bit
No AFT support
Eth. Ctrl 2x1000-BASE-T Cu PG-1862 PCI-X/64bit
*-cannot be applied
*1: Frequency will be changed by the spec of PCI card and number of cards mounted.
2
52
3
3
4
-
-2
Mount Priority Mountable Cards
4
1
43
-
43
34
123
Bus
12
1-
--- -
PCI
64bit/
100MHz*1
64bit/
133MHz*1
32bit/
33MH
z
PCI-X
Remarks
123 4 5
Full Height
3.3V 5.0V
PCI Slot
Priority
Max No.
of Mount
2
2
4
2
3
2
4
1
21
12
1
-
-- 1
4
4
43
1
2
1
-
-
-
-
Configuration Diagram
CPU
Xeon®
3.60EGHz/3.2EGHz
/ 3EGHz (2MB)
PCI Slots
PCI5 64bit/33MHz
PCI4 64bit/133MHz *2
PCI3 64bit/133MHz *2
PCI2 64bit/100MHz *2
PCI1 64bit/100MHz *2
5 inch Bay 3
5 inch Bay 2
5 inch Bay 1
CD-ROM Drive / FDD
Hard Disk 3.5inch Bay (hot plug)
Standard Drive Cage
Mountable I/O Options
High
Low
Memory
DIMM Slot 2A
DIMM Slot 2B
DIMM Slot 1A
DIMM Slot 1B
DIMM Slot 0A
DIMM Slot 0B
Xeon®
3.60EGHz/3.2EGHz
/ 3EGHz (2MB)
Bay 1
SCSI
Bay 2
SCSI
Bay 3
SCSI
Bay 4
SCSI
Bay 5
SCSI
Bay 6
SCSI
3.5 inch HDD Bay 6
(hot plug)
3.5 inch HDD Bay 5
(hot plug)
3.5 inch HDD Bay 4
(hot plug)
3.5 inch HDD Bay 3
(hot plug)
3.5 inch HDD Bay 2
(hot plug)
3.5 inch HDD Bay 1
(hot plug)
Hard Disk 3.5inch Bay (hot plug)
with Internal HDD Unit Bay Conversion kit (PG-BC102
)
Bay 7
SCSI
Bay 8
SCSI
Bay 9
SCSI
Power Supply Unit
*1
PRIMERGY TX200 S2

Other manuals for Fujitsu PRIMERGY TX200 S2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY TX200 S2 and is the answer not in the manual?

Fujitsu PRIMERGY TX200 S2 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY TX200 S2
CategoryServer
LanguageEnglish

Related product manuals