1
PRIMERGY RX300 S2 User’s Guide
1
2
3
4
5
6
7
9
8
Areas Covered
Before Reading This Manual
This section explains the notes for your safety and conventions used in this manual. Make sure to read this
section.
Chapter 1
Overview
This chapter explains component names and basic operations of this server, as well as an
overview of the software provided with this server. In addition, the workflow, from placing
the server to starting the operation, is also described.
Chapter 2
Checking before OS Installation
This chapter explains the preparation on the server and cautions necessary before OS
installation. Please read this chapter before starting installation.
Chapter 3
OS Installation Using ServerStart
This chapter explains how to install the OS on the server using ServerStart.
Chapter 4
Manual OS Installation
This chapter explains how to install the OS without using ServerStart.
Chapter 5
Operations after OS Installation
This chapter explains the operations to be performed after OS installation. Be sure to perform
those operations before operating the server.
Chapter 6
High Reliability Tools
For stable PRIMERGY server operations, we recommend that high reliability tools be
installed. This chapter explains the installation and necessary settings of high reliability tools.
Chapter 7 Installing Internal Options
This chapter explains how to install internal options on this server.
Chapter 8
Hardware Configuration/Utilities
This chapter explains how to make the environment settings necessary to operate the server.
Chapter 9
Operation and Maintenance
This chapter explains the operations necessary after starting to use this server as well as daily
care and maintenance.
Appendix
This appendix explains the specifications for the server and internal options. It also covers
how to recycle the products.

Table of Contents

Other manuals for Fujitsu Primergy RX300 S2

Questions and Answers

  • B
    Brianna MichaelAug 20, 2025
    Why are serial ports not recognized properly in Device Manager on my Fujitsu Server?
    • C
      Christina PowellAug 20, 2025
      This issue may arise if the Serial 1 and Serial 2 settings have been altered. To resolve this, remove all serial ports listed in Device Manager and then restart your Fujitsu Server.
  • D
    David ShafferAug 22, 2025
    What to do if nothing is displayed on the screen of my Fujitsu Primergy RX300 S2?
    • T
      Tara YoungAug 22, 2025
      If your Fujitsu Server displays nothing on the screen, check the following: * Ensure the display cable is properly connected. * Verify that the brightness and contrast settings on the display are correctly adjusted. * Note that the issue may be related to an error in the system memory area.
  • A
    Ana ChapmanAug 25, 2025
    What to do if keyboard controller error appears on Fujitsu Primergy RX300 S2?
    • J
      Jeff GambleAug 25, 2025
      If you encounter a keyboard controller error on your Fujitsu Server, the keyboard may be faulty. Try replacing the keyboard or mouse. If the error persists after replacement, the baseboard likely needs to be replaced.
  • K
    Kent ThompsonAug 26, 2025
    What does 'Critical memory error occurred - system halted' mean on Fujitsu Primergy RX300 S2?
    • J
      Judith LewisAug 26, 2025
      If your Fujitsu Server displays a 'Critical memory error occurred - system halted' message, it indicates a memory issue. First, restart the server. If the message reappears, consult the error log and replace the defective memory module.
  • J
    John JohnsonAug 28, 2025
    How to resolve LAN Operation Fails on Fujitsu Server?
    • K
      Kayla SextonAug 28, 2025
      If LAN operation fails or an error message appears during LAN driver installation on your Fujitsu Server, it may be due to a conflict between system resources, including the LAN and other expansion cards. Try deleting all LAN drivers and ensure there are no conflicts between system resources.
  • E
    eric43Aug 29, 2025
    Why is the screen shaking on my Fujitsu Server display?
    • V
      Valerie KennedyAug 30, 2025
      If the screen on your Fujitsu Server display is shaking, it might be due to interference from a strong magnetic field. Devices like televisions or speakers placed near the display can cause this. Move such devices further away from the display, and avoid using cell phones near the display.
  • T
    Tyrone HayesAug 31, 2025
    What does 'Memory type mixing detected' mean on Fujitsu Primergy RX300 S2?
    • J
      Joyce SellersSep 1, 2025
      If your Fujitsu Server shows a 'Memory type mixing detected' message, it means the memory installation configuration is incorrect. Ensure that the same type of memory is installed in the slots of the same bank.
  • C
    cummingsjosephSep 2, 2025
    How to fix distorted screen display on Fujitsu Primergy RX300 S2 Server?
    • L
      Lisa EspinozaSep 2, 2025
      If the screen display on your Fujitsu Server is distorted, especially during 3D program execution (or if the 3D program terminates abnormally), set the Color quality in screen properties to something other than True Color (32 bits).
  • D
    Deborah MosleySep 4, 2025
    What to do if Fujitsu Primergy RX300 S2 Server POST stops with 'Expansion ROM not initialized' message?
    • K
      Kelly JohnsonSep 4, 2025
      To resolve the "Expansion ROM not initialized..." message during POST on your Fujitsu Server, change [Reset Configuration Data] to [Yes] in the BIOS Setup Utility, found under "8.2.5 Advanced Menu".
  • S
    Stephanie ChungSep 6, 2025
    What to do if Fujitsu Primergy RX300 S2 Server cannot collect the memory dump?
    • T
      tiffany69Sep 6, 2025
      If your Fujitsu Server cannot collect the memory dump, check the settings of the paging file and memory dump file.

Summary

Areas Covered

Chapter 1 Overview

Introduces component names, basic operations, and software overview.

Chapter 2 Checking before OS Installation

Covers server preparation and cautions for OS installation.

Chapter 3 OS Installation Using ServerStart

Details OS installation using ServerStart.

Chapter 4 Manual OS Installation

Explains manual OS installation.

Chapter 5 Operations after OS Installation

Covers post-OS installation operations.

Chapter 6 High Reliability Tools

Recommends and explains high reliability tools.

Chapter 7 Installing Internal Options

Details installing internal options.

Chapter 8 Hardware Configuration;Utilities

Explains environment settings for server operation.

Chapter 9 Operation and Maintenance

Covers operations, daily care, and maintenance.

Chapter 4 Manual OS Installation

4.1 Creating Driver Disks

Details the process of creating necessary driver installation disks.

4.2 Starting Manual Installation

Explains step-by-step procedures for manual OS installation.

Chapter 6 High Reliability Tools

6.1 Server Monitoring Tool [ServerView]

Introduces ServerView for monitoring server hardware status.

6.2 Solving Problems Early [DSNAP]

Introduces DSNAP for collecting failure investigation information.

Chapter 7 Installing Internal Options

7.3 Installing a CPU

Guides on installing a CPU, including socket locations and procedures.

7.4 Installing Memory Modules

Guides on installing memory modules, including slot locations and order.

7.5 Installing Expansion Cards

Explains how to install expansion cards into PCI slots.

7.6 Installing an Internal Hard Disk Unit

Guides on installing internal hard disk units into storage bays.

7.7 Installing Internal Backup Device

Guides on installing internal backup devices into storage bays.

7.8 Installing a Parallel Port

Guides on installing an extension parallel port option.

Chapter 8 Hardware Configuration;Utilities

Chapter 9 Operation and Maintenance

Fujitsu Primergy RX300 S2 Specifications

General IconGeneral
Processor Sockets2
ChipsetIntel 5000P
Network2 x Gigabit Ethernet
Form Factor2U Rackmount
ProcessorIntel Xeon 5000/5100/5300 series
StorageSAS or SATA HDD 2.5"/3.5"
RAID SupportOptional RAID controller
Operating System SupportWindows Server, Linux
Power SupplyRedundant power supply optional