159
PRIMERGY RX300 S2 User’s Guide
5
Operations after OS Installation
5.6.4 Cautions on Using the Teaming (SLB (Auto-Fallback
Disable)) Function
When a primary adapter is recovered from a failure during standby operation, auto-fallback is not
performed for the primary adapter. Communication is continued with the standby adapter.
To return to the communication using the primary adapter, perform the following operation.
1 Start up BACS. The procedure differs depending on the OS being used.
For Windows Server 2003
1. Click [Start] [Control Panel] [Broadcom Control Suite 2].
For Windows 2000 Server
1. Click [Start] [Settings] [Control Panel].
The [Control Panel] window appears.
2. Start up "Broadcom Control Suite 2".
2 Check that communication is performed with the [standby adapter] on the
Teamed Up adapter tree.
The currently communicated adapter is displayed with a mark.
3 Check that the primary adapter is running properly on the Teamed Up adapter
tree.
The primary adapter that is running properly is displayed with a mark.
If the primary adapter is not running properly, a mark is displayed.