System configurator and order-information guide
PRIMERGY TX200 S7           Status 2014-01-30
Floorstand System Rack System
without CPU, Memory and hot plug PSU without CPU, Memory and hot plug PSU - No Rackmount Kit included !
- One CPU ( first CPU ) has to be configured 
- One CPU ( first CPU ) has to be configured  - The Rackmount Kit or the
   additionally for a base configuration    additionally for a base configuration   option no Rackmount Kit has
- One memory kit per CPU has to be 
- One memory kit per CPU has to be 
  to be ordered separately
   configured for a base configuration    configured for a base configuration
LFF Base Unit standard S26361-K1404-V101 LFF Base Unit standard S26361-K1404-V501
 - 3 std fans and std PSU  - 3 std fans and std PSU
 - 4-port SAS backplane for 4x 3.5" hot plug SAS
 - 4-port SAS backplane for 4x 3.5" hot plug SAS
   or SATA HD`s incl. cables for connection to the     or SATA HD`s incl. cables for connection to the 
   modular or onboard controllers
   modular or onboard controllers
LFF Base Unit redundant S26361-K1404-V201 LFF Base Unit redundant S26361-K1404-V601
 - 3 std fans plus 1 std fan for redundancy  - 3 std fans plus 1 std fan for redundancy
 - 1 hp PSU has to be added  - 1 hp PSU has to be added
 - 4-port SAS backplane for 4x 3.5" hot plug SAS
 - 4-port SAS backplane for 4x 3.5" hot plug SAS
   or SATA HD`s incl. cables for connection to the     or SATA HD`s incl. cables for connection to the 
   modular or onboard controllers
   modular or onboard controllers
SFF Base Unit standard S26361-K1404-V301 SFF Base Unit standard S26361-K1404-V701
 - 3 std fans and std PSU  - 3 std fans and std PSU
 - 8-port SAS backplane for 8x 2.5" hot plug SAS
 - 8-port SAS backplane for 8x 2.5" hot plug SAS
   or SATA HD`s incl. cables for connection to the     or SATA HD`s incl. cables for connection to the 
   modular or onboard controllers
   modular or onboard controllers
SFF Base Unit redundant S26361-K1404-V401 SFF Base Unit redundant S26361-K1404-V801
 - 3 std fans plus 1 std fan for redundancy  - 3 std fans plus 1 std fan for redundancy
 - 1 hp PSU has to be added  - 1 hp PSU has to be added
 - 8-port SAS backplane for 8x 2.5" hot plug SAS
 - 8-port SAS backplane for 8x 2.5" hot plug SAS
   or SATA HD`s incl. cables for connection to the     or SATA HD`s incl. cables for connection to the 
   modular or onboard controllers
   modular or onboard controllers
Cables included in basic unit
Cable for CD/DVD is included
All cables for connection of HDD Backplane are included
Cables for USB Backup Drives are automatically provided
 if a USB Backup Drive is ordered.
S26361-F3552-E1  Only 1 TPM per system.
TPM Module TPM Module Loose delivery for later
Trusted Platform Module on Motherboard
Trusted Platform Module on Motherboard integration possible.
Use according to import restrictions Use according to import restrictions
max. 1x per system max. 1x per system
S26361-F3552-L1 
TPM Module add-on kit
C B for later integration (loose delivery)
Trusted Platform Module on Motherboard
Use according to import restrictions
Fujitsu PRIMERGY Server 8 of 28