Cut the Discharge pipe Cut the Suction pipe Removethe COMP NUTS. (3 places)
in this range. in this range. Remove the COMPLESSOR by lifting.
Caution
Keep the shape better.
There is a possibility of catching fire to oil when removing by the welding without cutting.
Procedure for compressor installation.
Reverse procedure to removing the compressor.
Precautions for installation of compressor.
(1) When brazing, do not apply the flame to the terminal.
(2) When brazing, be sure to replace the air in the pipe with nitrogen gas to prevent forming oxidization scale.