What to do if the 2nd zone sensor is not configured on my Fujitsu Waterstage WOYK112LCTA?
- HheathernguyenAug 3, 2025
If the 2nd zone sensor is not configured (if 2nd circuits kit), it's because of BX31. Set the parameter 5700 to 2, 4 or 6.
What to do if the 2nd zone sensor is not configured on my Fujitsu Waterstage WOYK112LCTA?
If the 2nd zone sensor is not configured (if 2nd circuits kit), it's because of BX31. Set the parameter 5700 to 2, 4 or 6.
Outlines requirements for appliance installation and maintenance by professionals.
Details on connecting refrigerant pipes, including materials, lengths, and precautions.
Guidelines for positioning and clearances of the outdoor unit to ensure proper operation.
Recommendations for installing the hydraulic unit, considering room requirements and clearances.
Essential rules and necessary tools for handling refrigerants and making connections.
Steps for creating a vacuum and filling the system with refrigerant R410A.
Steps for filling the hydraulic circuit with water and removing air.
Detailed guide for connecting electrical wires to the single-phase outdoor unit.
Detailed guide for connecting electrical wires to the three-phase outdoor unit.
Instructions for connecting electrical components to the hydraulic unit.
Lists common faults indicated on the hydraulic unit's display and their potential causes.
Describes error codes identified by LED flashes on the single-phase outdoor unit.
Describes error codes indicated by LED flashes on the three-phase outdoor unit.
A checklist of essential checks before starting the heat pump installation.
Step-by-step guide for initial start-up, including preheating and system checks.
| Model | WOYK112LCTA |
|---|---|
| Type | Air-to-Water Heat Pump |
| Heating Capacity | 11.2 kW |
| Power Supply | 3-Phase, 400V, 50Hz |
| Refrigerant | R410A |
| Operating Temperature Range (Heating) | -20°C to 35°C |
| Weight (Outdoor Unit) | 108 kg |