Sensor
SB59
Carga
1
2
3
4
5
6
7
8
9
10
11
12
REFRIG
115 V
(12 V)
230 V
(24 V)
0
7 - 8
7 - 9
115V
230V
12V
24V
MT-512Ri MT-512RiL
72 mm
29 mm
Power
supply
Load
supply
9. WIRING DIAGRAM
COMMON
NO
NC
Dimension of the clipping
for setting of the instrument
in panel
IMPORTANT
According to the chapters of norm IEC 60364:
1: Install protector against overvoltage on the power supply.
2: Sensor cables and signal cables of the computer may be joined, but not in the same electric conduit
through which the electric input and the activation of the loads run.
3: Install transient suppressors (RC filters) parallel to the loads as to increase the product life of the
relays.
Note: The length of the sensor cable may be increased by the user up to 200 meters, using a PP 2 x 24
AWG cable. For immersion in water, use thermometric well.
Contact suppressor connection diagram
Suppressor
A1
A2
A1 e A2 are the
contactor coils.
Diagram for suppressor installation
for direct drive load inputs
Load
Suppressor
For direct activation the maximum
specified current should be taken
into consideration.
Suppressors on offer from Full Gauge Controls
ENVIRONMENTAL INFORMATION
Package:
The packages material are 100% recyclable. Just dispose it through specialized
recyclers.
Products:
The electro components of Full Gauge controllers can be recycled or reused if it is
disassembled for specialized companies.
Disposal:
Do not burn or throw in domestic garbage the controllers which have reached the end-of-
life. Observe the respectively law in your region concerning the environmental
responsible manner of dispose its devices. In case of any doubts, contact Full Gauge
controls for assistance.
PROTECTIVE :VINYL
This adhesive vinyl (included inside the packing) protects the instruments against
water drippings, as in commercial refrigerators, for example. Do the application after
finishing the electrical connections.
This adhesive vinyl (included inside the packing) protects the instruments against
water drippings, as in commercial refrigerators, for example. Do the application after
finishing the electrical connections.
Remove the protective paper
and apply the vinyl on the entire
superior part of the device,
folding the flaps as indicated by
the arrows.