4
Part # FA100 HEPA Filter
The HEPA filter is 99.97% efficient in removing particles as small as 0.3 from an airstream.
Particles of this size are respirable and can cause significant respiratory problems.
Replacement:
A HEPA’s service life is determined by the volume of sub-micron particles remaining in the airstream after
passing through the pre-filters. When properly protected, and depending on loading, HEPA filters often provide
months of service. Average service life is 2-4 months.
Part # FA201D Gas/Odor Filter
Most process plumes contain several gases, some odorous some not, some toxic at elevated concentrations
some completely harmless regardless of concentration. To ensure employee safety the type and concentration
of pollutants must be determined. Please contact Fumex Engineering for filter selection assistance. These filters
utilize a blended activated carbon and activated alumina impregnated with KMnO4 filter to capture and treat
gases/odors. This combination of materials provides protection across a broad range of gases commonly found
in industrial manufacturing processes.
GENERAL MAINTENANCE
1) The blower motor(s) is a sealed unit, 24,000 hr. MTBF rated. It is permanently lubricated and does not require
oiling keep it free of dust accumulations to prevent overheating.
2) Remove any loose accumulations of dust/debris from the air filter chamber periodically.
“This product employs overload protection (fuse). A blown fuse indicates an overload or short-circuit situation. If
the fuse blows, unplug the product from the receptacle. Replace the fuse as per the user servicing instructions
(use only 15-Amp fuse) and check the product. If the replacement fuse blows, a short circuit may be present, and
the product should be discarded or returned to an authorized service facility for examination and/or repair”
Remote Interface and Connectivity Function
The FA2 can be supplied with an optional interface package providing remote start/stop and filter monitoring
capabilities (Part # FA227). Please see instructions below for Relay Activation/De-Activation procedures and
refer to the drawing in Figure 1 for remote connections.
WARNING
To Prevent the Risk of Electrical Shock, Connect Remote Interface
Cable to 24v, Class 2 Power Supply Only”
WARNING
“Disconnect from All Power Supplies Before Servicing”