3
20
bintec User’s Guide Quick Install Guide
Configuration
Any existing configuration is ignored but not deleted; the default parameters of
ex works state will be used.
To reset your gateway proceed as follows:
1. Turn the power off your gateway.
2. Press the Reset button of the gateway.
3. Whilst pressing the Reset button, reconnect the gateway to the mains sup-
ply.
4. Watch the LEDs:
–First the Power and Status LEDs will light up.
The Ethernet LEDs (1 to 4) for ports that are connected to the Ethernet
will flash.
The boot sequence is started.
Release the Reset button after the Status LED lit up five times.
Now you can restart the gateway configuration as described starting from
“Configuration” on page 9.
Note
If also the user passwords are to be reset to ex works state, please follow the
following instructions:
1. Select option (4) D
ELETE CONFIGURATION of the BOOTmonitor and follow the
instructions (for details about the BOOTmonitor handling see bintec User’s
Guide chapter Gateway Management).
or
2. Carry out the reset procedure as decribed above and enter erase
bootconfig as L
OGIN into the login prompt and press Return. The password
is left empty. After pressing Return the gateway starts up with the boot se-
quence.
quick_reference.book Page 20 Tuesday, April 4, 2006 9:26 AM

Other manuals for Funkwerk bintec R230aw

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Funkwerk bintec R230aw and is the answer not in the manual?

Funkwerk bintec R230aw Specifications

General IconGeneral
BrandFunkwerk
Modelbintec R230aw
CategoryGateway
LanguageEnglish

Related product manuals