NEW BLT TRANSDUCERS
A
-9
Setting
For the locations of JP10 and JP11, see page A-1.
Board Frequency (kHz) Output (kW) Transducer JP10 and JP11 setting
2 28BL-6HR B
28
3 28BL-12HR C
2 38BL-9HR C
38
3 38BL-15HR E
2 50BL-12HR D
02P6204
MAIN
50
3 50BL-24HR E
S1
Board Frequency (kHz)
1 2 3 4
28/50 ON ON ON ON
38/50 OFF ON ON ON
50/88 ON OFF ON OFF
02P6204
MAIN
50/200 ON OFF OFF ON