4-3
4.2 Connecting of NBDP Terminal Unit
OP05-96 (IB-581)/OP05-100 (IB-583)
To use this equipment for the telex, the NBDP terminal unit is required.
Name: NBDP terminal set, Type: OP05-96, Code No.: 000-056-949
Name Type Code No. Qty Remarks
Terminal unit IB-581-02 000-043-350 1 set w/installation materials
DSP Board OP05-97 005-951-820 1 05P0751A
Name: NBDP terminal set, Type: OP05-100, Code No.: 000-056-956
Name Type Code No. Qty Remarks
Terminal unit IB-583 000-043-435 1 w/installation materials
DSP Board OP05-97 005-951-820 1 set 05P0751A
Inserting the DSP Board
1. Open the cover of the transceiver unit.
2. Remove the shield cover from the T-CPU Board (05P0732).
3. Attach the DSC Board (supplied) on J5 and J6 of the T-CPU Board.
Attach DSP
Board here.
T-CPU Board
J1
Location of DSP Board
4. Remount the shield cover.
5. Close the cover of the transceiver unit.
Mounting location for terminal unit
Leave sufficient space around the unit for operation and maintenance.
The temperature and humidity of the mounting location should be stable and moderate.
Keep the unit away from the high power radiotelephone and it’s feeder wire so that RFI
(Radio Frequency Interference) is minimum.