RC18xx
Battery Requirements
Current / RC1815 RC1825 RC1840
Equipment Calculation Amps Amps Amps
PP510 0.4A x 2 = 0.8 0.8 0.8
DSC-60 1.0A = 1
DP-6 1.6A = 1.6
AC Fail Lamp 0.3A = 0.3 0.3 0.3
Emer. Lamp 0.3A = 0.3 0.3 0.3
Felcom 15 RX 0.9A = 0.9 0.9 0.9
Felcom 15 TX 5A/2 = 2.5 2.5 2.5
IB-583 0.6A = 0.6 0.6
FS-1570 RX 0.8A = 0.8
FS-1570 TX 20A/2 = 10
FS-2570 RX 1.5A = 1.5
FS-2570 TX 35A/2 = 17.5
FS-5000 RX 3A = 3
FS-5000 TX 60A/2 = 30
FM-8500 RX 0.5A x 2 = 1 1 1
FM-8500 TX (6.25A/2) x 2 = 6.25 6.25 6.25
Amps Per Hour 23.45 31.65 47.65
* Method used for calculation: 1/2 of the current consumption necessary for
transmission + the current necessary for reception + current consumption of
any additional loads
3-3