5. RC1815/RC1825 Equipment Setup
5-2
5.2 DMC-5 (Optional Equipment)
Refer to the Operator’s/Installation Manual, DMC-5
5.2.1 General
The setup and testing of the DMC-5 should be completed last. This unit
expects all equipment, in the console, to already be operational.
1) After powering up the DMC-5 for the first time the screen should be as
shown above.
2) Press the [SET UP] key, then the 0 key four times.
3) Then press the [ENT] key.
5.2.2 VHF Input
1) Press the [SET UP] key, then the 4 [VHF] key.
2) Press the [SELECT] to highlight No.1, then press the [ENT] key.
5.2.3 MF/HF Input
1) The display should appear as shown above, if it does continue to step 2.
If the Pos: still shows NG, check the DMC-5 wiring and programming
of VHF No.1, which should be mounted in the console.
2) Press the [SET UP] key, then the 5 [MF/HF] key.
3) Press the [SELECT] key to highlight J3E, then press the [ENT] key.
*Watch* Pos: NG 00:00
Manual input ? [ SET UP ] Key
*Watch* Pos: manu 00:00
*Watch* Pos: auto 00:00
VHF