13. Additional Protective Features
a) Over Input Voltage Shut Off- When the 12 volt DC power
supply voltage exceeds 15.5±0.5 volts, the inverter will
automatically shut down.
b) Low Input Voltage Shut Off - When the 12 volt DC power
supply voltage drops below 10.5±0.3volts, the inverter will
automatically shut down,
c) Low Input Voltage Alarm - When the 12 volt DC power supply
voltage drops below 1±0.3volts, an audible alarm will sound.
d) Over Heating Self-lock - When the internal temperature
exceeds the regulated temperature due to the increase
of surrounding air temperature, the inverter will automatically
shut down. When the internal temperature drops below the
surrounding air temperature, the inverter will automatically
return to normal operation.
InverterManual_012411.indd 12 1/31/11 8:43:21 AM