EasyManua.ls Logo

FUXTEC FX-MS125 - Troubleshooting

FUXTEC FX-MS125
162 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Original Bedienungsanleitung FUXTEC FX-MS125_de_en_fr_ita_es_rev01
64
35. Troubleshooting
1. Difficulties during commissioning
Situation
Cause
Solution
No ignition
spark
Spark plug
Carbon deposit between the
diodes of the spark plug
Clean the spark plug.
Adjust the gap
0.6~0.7mm, replace
the spark plug
other
Ignition coil defective flywheel
magnet too weak
Replace the ignition
coil or flywheel
Weak
ignition
spark
Compression
Too much petrol in the combustion
chamber, lousy fuel or water in
the tank
Remove the spark
plug and allow it to
dry, and replace the
fuel.
The carburettor does
not pump oil
anymore.
Oil line blocked
Cleaning the
carburettor and
cleaning the pipes
regular oil supply,
but weak
compression
Piston rings are worn, the spark
plug is not screwed down, the
cylinder head is not tight, wrong
valve clearance or ignition timing.
Replace the screw
tight to replace or
adjust
regular oil supply
and proper ignition
spark
Poor contact between the ignition
cap and spark plug
Replace or check