FWE standard models operate on 110/120 volt,
60 Hz, 1 ph, A.C. (unless ordered otherwise), and are equipped
with a three prong grounding cord plug for your protection against
possible shock hazards. Be sure to plug only into a properly
grounded three prong wall receptacle. If you have any questions
with regard to adequate wiring or grounding in your building,
a qualified electrician should be contacted before using your
cabinet. The amperage of your cabinet is stamped on the
name plate attached to the unit.
DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR REMOVE
THE GROUNDING PRONG FROM THE CORD PLUG.
WARNING: ONLY A QUALIFIED ELECTRICIAN SHOULD
ATTEMPT TO REPAIR OR REPLACE ELECTRICAL
COMPONENTS OR WIRING.
BE SURE THAT MODEL IS UNPLUGGED FROM ELECTRICAL
SOURCE BEFORE REMOVING CONTROL PANEL.
FWE MOBILE REFRIGERATORS AND FREEZERS
SERIAL AND MODEL NUMBER
INSTALLATION
UNPACKING
ELECTRICAL REQUIREMENTS AND GROUNDING
These numbers are found on the nameplate (serial tag) affixed
to the unit. The serial tag is located by the electrical cord.
Please record them on the back of this booklet. When ordering
parts and/or service, you will need to provide this information.
The voltage and amperage of the unit are also stamped on the
serial tag.
After uncrating your cabinet, remove all tape and padding
which held all doors, shelves, racks, cord, etc., in place
during shipment.