9
Installation and connection
en
Before using the appliance for the
first time
1 Remove information material, adhesive tape and
protective film.
2 Clean the appliance.
~
"Cleaning" on page 27
Water connection
Caution!
– Installation and connection of the appliance must
be carried out by qualified technicians according to
the installation instructions supplied.
– To avoid damage to the appliance and to ensure its
proper functioning, it should only be connected to a
drinking water system.
– To avoid water damage, a shut-off valve must be
installed.
Water pressure of drinking water system
Caution!
If the water pressure exceeds the maximum value, a
pressure relief valve must be installed between the
drinking water connection and the hose set to avoid
damage to the appliance.
Note: If the water pressure is too low, this will impair
the appliance functions.
▯ Min. 0.2 Mpa (2 bar/29 psi)
▯ Max. 0.8 Mpa (8 bar/116 psi)
Electrical connection
Caution!
Do not connect the appliance to electronic energy saver
plugs.
Note: You can connect the appliance to mains-
controlled and sine-controlled inverters.
Mains-controlled inverters are used for photovoltaic
systems which are directly connected to the national
grid. Sine-controlled inverters must be used for isolated
applications.Isolated applications, e.g. on ships or in
mountain lodges, which are not directly connected to
the national grid.
1 After installing the appliance, wait at least 1 hour
before connecting it to avoid damaging the
compressor.
2 Connect the appliance to a correctly installed
socket.
The socket must comply with the following data:
Outside Europe: Check whether the indicated
current type of the appliance corresponds with the
values of your power supply. The appliance
specifications are specified on the rating plate.
~ "Getting to know your appliance" on page 10
3 Connect the appliance to a socket near the
appliance.
The socket must also be freely accessible after
installation of the appliance.
m Warning – Risk of electric shock!
If the length of the mains cable is insufficient, do
NOT use multi-outlet power strips or extension
leads.Instead, please contact Customer Service for
alternative solutions.
Socket with 220 V ... 240 V
Protective
conductor
50 Hz
Fuse 10 A ... 16 A