The mixing process using the UNGUATOR
®
e/s
Any irregularities are indicated a fault message on the display. The meaning of the
individual fault messages are listed in the table below.
Size of the UNGUATOR
®
Jar
Type of formulation
15 to 20 ml 30 to 100 ml 200 to 300 ml 500 ml
Emulsion / + 03:10 04:10 06:45 08:15
Normal 02:10 03:10 05:45 07:15
Suspension < / > 2 % 04:10 05:15 08:15 10:20
Suppositories 02:10 03:10 05:45 07:15
Gel
25 min 6 times 10 strokes each with 5 breakes á 04:30 at 1750 rpm
Tabelle 3-3: Minimum values for mixing time at speed step 5 in min:sec
Size of the UNGUATOR
®
Jar
Type of formulation
15 to 20 ml 30 to 100 ml 200 to 300 ml 500 ml
Emulsion / + 10:10 13:30 22:00 27:00
Normal 06:45 10:10 18:40 23:45
Suspension < / > 2 % 13:30 16:55 27:00 33:45
Suppositories 06:45 10:10 18:40 23:45
Tabelle 3-4: Minimum values for mixing time at speed step 1 in min:sec