TROUBLESHOOTING
Problem Causes Solution
Energizer has started to run
slowly
The internal temperature of
the energizer is too high
Mount the energizer in a cool
area, out of direct sun and
with adequate ven la on
Displaying Error 11 Mains voltage is too high Have your power supply
checked by a professional
electrician
Displaying Error 12 Mains voltage is too low Have your power supply
checked by a professional
electrician
Displaying Error 14 - 19 Internal energizer fault Turn energizer off for 30
seconds then turn back on. If
the error remains return the
energizer to your Gallagher
dealer for servicing.
Energizer output voltage is
low
There is a fault on the fence Remove any excess grass
growth or short circuits on
the fence.
Earth voltage is too high Earth system is inadequate Check connec ons to the
earth system. Add extra
earth stakes.
No output and display shows
( - - )
Energizer is in standby mode Exit standby mode by
pressing the standby bu on
on the controller