Perform dry cycle mold and full tonnage 3-4 times, ensuring no wires are pinched.
Turn off individual temperature zones before proceeding.
Turn on the main disconnect to supply power.
Select specific zones or all zones for operation by pressing the first and last zone buttons.
Set temperature for selected zones and apply to all selected zones.
Select automatic or manual operation mode for zones, entering '0' for automatic.
Turn on zone power switches, applying power to manifolds first if required.
Monitor zone status for low temperature alarms or set point holding.
Displays actual zone value, degree C/F, deviation, and Amps.
Controls for temperature setpoint, manual % setpoint, and trim adjustments.
Temporarily increase zone temperature or set zones to standby.
Switch between automatic (0) or manual (1) temperature control.
Shows zone selection, status, high/low temp alarms, and set points.
Displays status for High/Low Temperature, Thermocouple, Open/Shorted Heater, and Fuse.
Press both Select buttons simultaneously to enter Advanced Setup Mode.
Use View Area Select to scroll up and Change Area Select to scroll down.
Use '+' or '-' keys to make changes and 'Enter' to confirm.
Options to restore or save mold set up configurations.
Configure boost set points and boost time for temporary temperature changes.
Set the maximum temperature value for automatic operation.
Configure set points for temperature deviation alarms.
Define the set point for standby mode operation.
Adjust control algorithm settings, including tuning parameters.
Configure time settings for thermocouple pinch detection.
Enable or disable slaved power-up for zones to reach set point simultaneously.
Select temperature units between Fahrenheit and Celsius.
Specify thermocouple input type (J or K).
Select the host computer communication protocol.
Configure the controller's address on the Euromap 17 network.
Set the communication speed for host computer connection.
Manage security code levels for access and changes.
Activate zone finder to identify T/C inputs and output modules.
Perform an LED test for troubleshooting purposes.
View error status and diagnostic codes for troubleshooting.
Display software version numbers for controller components.
Indicate and adjust security levels (Lockout, Operator, Supervisor).
Understand indicators for High/Low Temperature, Thermocouple issues, and Heater problems.
Diagnose Thermocouple Open, Reversed, or Pinched conditions.
Diagnose Shorted Heater or Open Heater connection problems.
Procedure to check and identify open fuses on the output module.
Perform resistance checks on thermocouples and heaters.
Steps to identify if the fault lies within the controller unit itself.
Locate and identify key controller components like power supply and output modules.