Do you have a question about the Gantner Q.bloxx A116 and is the answer not in the manual?
| Input Channels | Analog |
|---|---|
| Number of Channels | 16 |
| Communication Interface | Ethernet |
| Operating Temperature | -20°C to +60°C |
| Input Type | Voltage |
| Sampling Rate | Up to 1000 Hz per channel |
| Power Supply | 10 to 30 V DC |
| Isolation | 500 V DC channel-to-bus |
| Resolution | 24 bit |
Defines the intended applications for Q.series products in industrial and experimental test engineering.
Highlights risks associated with high voltages (up to 1200V) on specific modules.
Warns about residual risks from improper use by untrained personnel.
Explains the meaning of hazard symbols (Danger, Warning, Caution, Notice) used in the manual.
Explains how to connect and operate Q.bloxx modules using the Q.gate Test Controller.
Details how to connect and operate Q.bloxx modules using the Q.pac Test Controller.
Covers the base unit's function, mounting, and operating modes like unconfigured or hot swap.
Details the voltage requirements and connection procedure for supplying power to the modules.
Details pin assignments and connection methods for the Q.bloxx A101 module.
Details pin assignments and connection methods for the Q.bloxx A102 module.
Details pin assignments and connection methods for the Q.bloxx A103 module.
Details pin assignments and connection methods for the Q.bloxx A104 module for thermocouples or voltages.
Details pin assignments and connection methods for the Q.bloxx A105 module for resistance measurements.
Details pin assignments and connection methods for the Q.bloxx A106 module.
Details pin assignments and connection methods for the Q.bloxx A107 module.
Details pin assignments and connection methods for the Q.bloxx A108 module.
Details pin assignments and connection methods for the Q.bloxx A109 module.
Details pin assignments and connection methods for the Q.bloxx A111 module.
Details pin assignments and connection methods for the Q.bloxx A116 module.
Details pin assignments and connection methods for the Q.bloxx A123 module, highlighting high voltage safety.
Details pin assignments and connection methods for the Q.bloxx A124 module for thermocouples.
Details pin assignments and connection methods for the Q.bloxx A127 module, highlighting high voltage safety.
Details pin assignments and connection methods for the Q.bloxx A128 module, highlighting high voltage safety.
Details pin assignments and connection methods for the Q.bloxx D101 module's digital I/O.
Details pin assignments and connection methods for the Q.bloxx D104 module's digital inputs.
Details pin assignments and connection methods for the Q.bloxx D105 module's digital outputs.
Details pin assignments and connection methods for the Q.bloxx D107 module's digital inputs.
Explains how to use the test.commander software for module and Test Controller configuration.
Explains how to configure analog input modules and set sensor parameters.
Details setting parameters like sensor type, units, and scaling for analog inputs.
Explains how to configure digital inputs and outputs, including status indicators and process outputs.
Guides on configuring analog output modules, specifying voltage or current outputs.
Explains settings for Q.gate and Q.pac Test Controllers, including interfaces and synchronization.
Provides instructions on updating firmware for modules and Test Controllers.
Explains how to scale sensor signals to physical units, including voltage and strain gauge data.
Details the process of scaling voltage signals and strain gauge bridge measurements.
Guides on using the strain gauge calculator for scaling, including gauge factor entry.