EasyManua.ls Logo

Gardasoft Vision PP420 - Page 19

Gardasoft Vision PP420
26 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Report the configuration
ST
Typical output is:
CH 1, MD 2, IP 4, CS 0.100A, SE 75.0, DL 2.0us, PU 300.0us, RT 500.0us, FL 1
CH 2, MD 0, IP 2, CS 0.100A, SE 25.8, DL 1.000ms, PU 1.000ms, RT 0.0us, FL 0
CH 3, MD 0, IP 1, CS 0.100A, SE 50.0, DL 1.000ms, PU 1.000ms, RT 6.000ms, FL 4
CH 4, MD 1, IP 4, CS 0.100A, SE 100.0, DL 100.0us, PU 1.000ms, RT 0.0us, FL 5
Where the numeric values are:
CH Channel number
MD Mode: 0 = continuous, 1 = pulse, 2 = switched
IP Trigger input: 1, 2, 3, 4
CS Current rating of the light
SE Brightness percentage setting
DL Pulse delay
PU Pulse width
RT Retrigger delay
Enable Ethernet Messages
GTm
m = 0 to disable Ethernet messages
= 1 to enable Ethernet messages
When Ethernet messages are enabled, any error reports are sent to the most recent UDP or TCP
address from which a command has been received. See appendix B.
Read any error messages
GR
If Ethernet messages are not enabled, the last error number can be read by this command. Any
error displayed on the unit is cleared, so if there was a lighting error, the PP420 will resume auto-
sensing on that channel.
The reply is of the form:
Err 45 Error 45 was the last error
Err 0 No error has occurred since the last GR command
Report the version of firmware running in the PP420
VR
This command returns the firmware version. For example:
PP420 (HW001) V002
Clear Settings
CL
Clears the output channel configuration. This excludes the Ethernet settings. For each channel, if
the AUTO_SENSE flag is set, then the flag and the current rating are preserved.
Set/Clear the Webpage Password
EY
EY asc1, asc2, asc3, asc4, asc5, asc6