APPENDIX 3: TEMPERATURE SENSOR RESISTANCE DATA
Temp °F Temp °C Min. Rate
k
Standard
Rate k
Max. Rate
k
212 100 11.490 13.060 14.810
302 150 2.803 3.161 3.434
392 200 0.950 1.000 1.050
482 250 0.3572 0.3865 0.4171
R(200)°C = 1 k ± 5%
Temperature Sensor Resistance
Note:
These resistances will only be apparent in a stable cavity temperature as the
sensor has a slow response time.