Get Started

Tools Needed

Lists the required tools for initial setup, such as a small screwdriver.

How to Use

Maintenance

Replacing the Battery

Instructions on how to replace the batteries when the detector indicates low power.

Cleaning & Storage

Guidance on cleaning the detector exterior and sensor, and ideal storage conditions.

Product Specifications

Overview

The GasKnight Pro Gas Detector is a handheld device designed to detect various types of gas leaks, providing a crucial safety measure for users. While it aims to reduce the risk associated with gas leaks, it emphasizes that it cannot guarantee complete safety and encourages users to prevent leaks at their source. The device is intended for use by individuals who understand its operation and limitations, with a legal disclaimer absolving the manufacturer, importer, reseller, or distributor from liability for any direct, indirect, punitive, incidental, special, or consequential damages arising from its use or misuse.

Function Description

The primary function of the GasKnight Pro is to detect the presence of combustible gases and other volatile substances. It is equipped with a flexible hose and a sensor cap at its end, allowing users to precisely approach suspected leak sources. The device features a sensitivity dial that enables users to adjust the detection level, making it versatile for different gas types and leak severities.

Upon activation, the detector undergoes a warm-up process, indicated by an initial alarm sound that gradually slows down or stops as it stabilizes. The "Ready" indicator displays a solid green light when the device is operational and has sufficient battery life. Conversely, the "Alarm" indicator illuminates red when a gas leak is detected, signaling an active alarm.

The GasKnight Pro is capable of detecting a wide range of gases and vapors, including:

  • Natural Gas
  • Propane
  • Butane
  • Methane
  • Ethane
  • Steam
  • Acetone
  • Alcohol
  • Hydrogen
  • Ammonia
  • Gasoline Vapor
  • Sulfide
  • Organic Solvent Vapor
  • Paint Thinner
  • Naphtha
  • Volatile Industrial Solvent

The device's operation relies on a low-power semiconductor sensor that responds to the presence of these substances. The sensitivity can be fine-tuned to achieve an ideal ticking sound, indicating that the detector is balanced on the edge between alarm and non-alarm status, ready to detect even slight exposures to gas. A faster ticking sound signifies higher sensitivity, while a slower tick indicates lower sensitivity.

Usage Features

To begin using the GasKnight Pro, users must first install four AA 1.5V alkaline batteries, ensuring correct polarity. Once the batteries are secured, the device can be powered on by pressing the power button.

  1. Sensitivity Adjustment: The sensitivity dial should be initially set to a halfway point or slightly less, between maximum (+) and minimum (-) sensitivity. This allows for an initial calibration.
  2. Warm-up Process: After powering on, the detector will emit a constant ringing sound, which is part of its normal warm-up. This process typically lasts about one minute or until the sensitivity level resets, indicated by the alarm noise slowing to a tick or stopping. To minimize noise during warm-up, headphones can be plugged into the earphone jack.
  3. Setting Ideal Sensitivity: For natural gas or propane detection, the ideal sensitivity level is often where a slow ticking sound can be heard. This indicates the device is optimally poised for detection. Users can adjust the dial to achieve a faster tick for higher sensitivity or a slower tick for lower sensitivity, depending on the specific detection needs. A typical tick rate in a normal environment is between 2-8 ticks per second.
  4. Leak Detection: Once the sensitivity is set, the user can slowly approach the suspected gas leak source with the sensor cap. As the sensor is exposed to gas, the tick rate will accelerate, eventually leading to a continuous ringing alarm.
  5. Silencing the Alarm: If an alarm is triggered, it can be silenced by:
    • Reducing the sensitivity level by turning the dial counterclockwise.
    • Moving the detector to fresh air and allowing the gas or fumes to dissipate from the sensor, which may take 5 seconds to 1 minute.
    • Powering off the detector, though this is not recommended unless usage is complete.

The device also includes a probe reset/detectability control, allowing for further fine-tuning of its detection capabilities. Its extra-long and flexible hose (15.5 inches) enhances its utility by enabling access to hard-to-reach areas. The GasKnight Pro is designed with explosion and fire-proof features for added safety.

Maintenance Features

Proper maintenance ensures the longevity and accuracy of the GasKnight Pro.

  1. Battery Replacement: The "Ready" light serves as a battery indicator. If it glows yellow, the battery is low, and replacement is recommended soon. If the "Ready" light is not illuminated at all, the batteries are completely drained and must be replaced for the unit to function.
  2. Cleaning and Storage:
    • The plastic exterior should be cleaned only with fresh water.
    • The sensor aperture, crucial for accurate measurements, must be kept clean. If it becomes dirty and affects performance, it should be cleaned gently with a soft brush.
    • Harsh cleaning products or erosive liquids like alcohol should never be used on the detector.
    • The device should not be immersed in water or any other liquid.
    • To prevent inaccurate measurements, the detector should not be exposed to excessive amounts of gas or water vapor, or environments with extremely high or low oxygen concentrations.
    • Proper storage is vital for sensor life and performance. The GasKnight Pro should not be stored in:
      • Extremely hot or cold environments (ideal storage temperature is around 70°F or 21°C).
      • Direct sunlight.
      • Humid environments (ideal storage humidity is 30-50%).
      • Excessively dusty or dirty areas.
      • Smoky environments.
      • Areas with high concentrations of chemicals (e.g., salt or sulfur).
    • Children should not be allowed to play with the batteries, and batteries should be kept away from hazardous environments.

The GasKnight Pro comes with a 1-year manufacturer warranty, with an option for a 1-year extension upon registration. However, the warranty may be voided if there is unauthorized disassembly, improper transportation or storage, customer-caused damage, or lack of proof of purchase.

GasKnight Pro Specifications

General IconGeneral
Explosion-proof GradeExd II CT6
Sensor TypeCatalytic
Power Consumption<3W
Output Signal4-20mA, RS485
Working Temperature-20℃~50℃
Working Humidity10-95% RH (non-condensing)