6 7
OPERATION
TROUBLE SHOOTING
Problem Possible Reason Solution
Appliance does not work
(Green LED is not glowing)
Flexible ducting not
attached
Fully attach the outlet flexible duct. Ensure
it is locked in place - twist anti-clockwise
No fuse Insert 5A fuse
Faulty fan Check fuse & battery charge
Battery flat Charge battery (6 hours)
Tilt switch activated Place on level ground and in area it can’t
be knocked over. Turn off and restart.
ODS activated Ensure appliance is in an open area and
not subject to a strong direct breeze. Turn
off and restart.
Appliance fuse blown Replace fuse (5 AMP)
Appliance does not work
(Green LED is glowing)
Faulty Fan Check fuse & battery charge
Igniter not working Push knob in and hold in with the switch
on. This takes about 10 seconds
Burner will not light
but fan is running
Air in gas line Purge gas line
Low gas pressure Install full canister or cylinder
Gas turned OFF Turn gas ON
Tilt switch activated Place on level ground and in area it can’t
be knocked over
ODS activated Ensure appliance is in an open area and
not subject to a strong direct breeze
Burner will not stay lit
Suspect thermocouple Repair or replace
Suspect valve Repair or replace
Wind exceeding 15kph Shelter from wind
ODS activated Ensure appliance is in an open area and
not subject to a strong direct breeze
Appliance fuse blown Replace fuse (5 AMP)
Unit switches off during use
Battery flat Charge battery
Temperature exceeded
safety cut off device
Turn off, wait 5 minutes and restart
Ambient temperature above 20˚C
NOTE: If the appliance cannot be adjusted to perform correctly it should not be used until serviced or repaired.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property
damage. Any modifications or adjustments made to product without prior authority from the manufacturer will
void any warranty claims. Read the set up and operating instructions thoroughly before installing or servicing
this equipment.
NOMINAL HOURLY GAS CONSUMPTION
Model Injector Orifice Injector Qty Gas Type Gas Pressure Gas Consumption BTU
CH100 Ø 0.45mm 1 LPG 2.75kPa 2.80 MJ/h 55g/h 2654