PerformanceDataSheet
SmartWaterFiltrationSystem
MWFCartridge
This system has been tested according to NSF/ANSI 42/53 for reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to
a concentration less than or equal to the permissible limit for water leaving the system, as specied in NSF/ANSI 42/53.*
(100% safety factors built in for unmetered usage)
Standard No. 42: Aesthetic Eects
Parameter
USEPA
MCL
Inuent
Challenge Concentration
Inuent
Average
Euent % Reduction
Min. Required
Reduction
Average Maximum Average Maximum
Chlorine - 2,0 mg/L +10% 1,96 mg/L 0,06 mg/L 0,11 mg/L 96,77% 94,74% > 50%
T & O - - - - - - - -
Particulate** - at least 10.000 particles/mL 6.400.000 #/mL 58.833 #/mL 150.000 #/mL 99,14% 97,97% > 85%
Standard No. 53: Health Eects
Parameter
USEPA
MCL
Inuent Challenge
Concentration
Inuent
Average
Euent % de reducción
Min. Required
Reduction
Average Maximum Average Maximum
Turbidity 1 NTU 11 +1 NTU*** 10,5 NTU 0,14 NTU 0,28 NTU 98,54% 97,20% 0,5 NTU
Cysts
99,95%
Reduction
Minimum 50.000 L 118.750 #/L < 1 #/L 4 #/L > 99,99% > 99,99% > 99,95%
Asbestos
99%
Reduction
107–108bras/L;
> 10µm
57 MF/L 0,996 MF/L < 1 MF/L 99,60% 99,39% > 99%
Lead at pH 6.5 0,015 mg/L 0,15 mg/L +10% 0,1567 mg/L < 0,001 mg/L < 0,001 mg/L 99,36% 99,29% 0,010 mg/L
Lead at pH 8.5 0,015 mg/L 0,15 mg/L +10% 0,1433 mg/L < 0,001 mg/L < 0,001 mg/L 99,30% 99,29% 0,010 mg/L
Mercury at
pH 6.5
0,002 mg/L 0,006 mg/L +10% 0,0059 mg/L 0,000350 mg/L 0,0007 mg/L 94,70% 87,50% 0,002 mg/L
Mercury at
pH 8.5
0,002 mg/L 0,006 mg/L +10% 0,0057 mg/L 0,000325 mg/L 0,0006 mg/L 93,20% 89,29% 0,002 mg/L
Alachlor 0,002 mg/L 0,04 mg/L +10% 0,0367 mg/L 0,00023 mg/L 0,0004 mg/L 99,34% 98,67% 0,002 mg/L
Lindane 0,0002 mg/L 0,002 mg/L +10% 0,0020 mg/L < 0,00002 mg/L < 0,00002 mg/L 99,00% 98,95% 0,0002 mg/L
2,4-D 0,070 mg/L 0,210 mg/L +10% 0,2033 mg/L 0,00337 mg/L 0,011000 mg/L 98,32% 94,50% 0,070 mg/L
Toxaphene 0,003 mg/L 0,015 mg/L +10% 0,0160 mg/L 0,00100 mg/L 0,001000 mg/L 93,44% 91,67% 0,003 mg/L
Benzene 0,001 mg/L 0,015 mg/L +10% 0,0145 mg/L 0,000500 mg/L 0,000500 mg/L 96,51% 95,83% 0,005 mg/L
Carbofuran 0,040 mg/L 0,080 mg/L +10% 0,0830 mg/L 0,001000 mg/L
0,001000 mg/L 98,78% 98,65% 0,04 mg/L
1,4
dichlorobenzene
0,075 mg/L 0,225 mg/L +10% 0,2283 mg/L 0,000500 mg/L 0,000500 mg/L 99,78% 99,77% 0,075 mg/L
Atrazine 0,003 mg/L 0,009 mg/L +10% 0,0087 mg/L < 0,0005 mg/L < 0,0005 mg/L 94,22% 93,33% 0,003 mg/L
* Tested using a ow rate of 0.50 gpm; pressure of 60 psi; pH of 7.5 ±0.5; temp. of 68°±5°F (20°±3°C).
** Measurement in Particles/ml. Particles used were 0.5-1 microns.
*** NTU=Nephelometric Turbidity units.
OperatingSpecications
Capacity: certied for up to 300 gallons (1135 l); up to six months for models without a replacement lter indicator light; up to one year for models with a replacement lter indicator light.
Pressure requirement: 40–120 psi (2.8–8.2 bar), non-shock.
Temperature: 33–100ºF (0.6–38ºC).
Flow rate: 0.5 gpm (1.9 lpm).
GeneralInstallation/Operation/MaintenanceRequirements
Flush new cartridge at full ow for 3 minutes to purge out trapped air.
Replace cartridge when ow becomes too slow.
SpecialNotices
Installation instructions, parts and service availability, and standard warranty are included with the product when shipped.
This drinking water system must be maintained according to manufacturer’s instructions, including replacement of lter cartridges.
Do not use with water that is micro biologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certied for cyst reduction may be used on
disinfected water that may contain lterable cysts.
The contaminants or other substances removed or reduced by this water treatment system are not necessarily in your water.
Check for compliance with the state and local laws and regulations.
Note that while the testing was performed under standard laboratory conditions, actual performance may vary. Systems must be installed and operated in accordance with manufacturer
recommended procedures and guidelines.