Programming   
3.14    FireShield Technical Reference Manual 
28. Enter the call back phone number 
Description: Specifies the phone number that is used for call 
back. 
Format: Up to 20 digits 
Default: Blank 
To enter the call back phone number: 
1.  Press Reset until the first digit of the phone number is 
displayed. 
2.  Press Panel Silence to save and advance to the next digit. 
  The trouble buzzer sounds a long beep as confirmation. 
3.  Press Reset until the next digit is displayed. 
4.  Press Panel Silence to save and advance to the next digit. 
5.  Repeat steps 3 and 4 until all digits are entered. 
Note: If less than 20 digits are entered, press Panel 
Silence again or Remote Disconnect to advance to the 
next program option. 
6.  When you press Reset at the last digit (20th digit), the 
system automatically advances you to the next program 
option. 
Event notification programming 
Event notification programming determines where events are 
sent. Events can be sent to the primary, secondary, or both 
central monitoring stations (CMS), or you can choose not to 
send the event at all. 
To program event notification, follow these general steps: 
1.  Select CMS locations for event reporting 
2.  Enter the system trouble restore code 
Note: If you are only using one central monitoring station and 
are using the default settings, no further programming is 
required. You can exit from programming by removing the 
program jumper. 
The first event notification programming option after 
completing “Select the restore option” is “Panel Tst Rcvr.” 
Twenty-one event receiver locations must be programmed 
using steps described below, under “Select CMS locations for 
event reporting.” 
CS Tst Rcvr 
CS AB Tst Rcvr 
Walk Tst Rcvr 
Drill Rcvr 
Reset Rcvr 
Program Mode Rcvr 
DACT Disab Rcvr 
Panel Sil Rcvr 
Signal Sil Rcvr 
Grd Fault Rcvr 
Low Batt Rcvr 
Mis Batt Rcvr 
Int Comm Tr Rcvr 
AC Fail Rcvr 
Charger Tr Rcvr 
Xfrmr 2 Tr Rcvr 
Aux Pwr Tr Rcvr 
Periph Trb Rcvr 
Line 1 Trb Rcvr 
Line 2 Trb Rcvr 
Delivery Tr Rcvr 
After programming the receiver locations, continue with the 
steps described under “Enter the system trouble restore code.” 
1. Select CMS locations for event reporting 
Description: Specifies which CMS receives each event. 
Settings: None 
 CS 1 
 CS 2 
  CS 1 and 2 
Default: CS 1 
To select the CMS locations for event reporting: 
1.  Press Reset to select the desired CMS location. 
2.  Press Panel Silence to save and advance to the next 
program option. 
  The trouble buzzer sounds a long beep as confirmation. 
3.  Repeat steps 1 and 2 to set the CMS location for each 
option. 
4.  When you reach the last option, proceed to "Enter the 
system trouble restore code" below. 
2. Enter the system trouble restore code 
Description: Sets the code that is transmitted to the CMS with 
trouble restoral events. 
Format: 1 digit (0 – 9 and A – F) 
Default: See Appendix E “Default event codes.” This can be 
changed if needed. 
To enter the system trouble restore code: 
1.  Press Reset to increment the restore code if it needs to be 
changed. 
2.  Press Panel Silence to save and advance to the next 
program option. 
  The trouble buzzer sounds a long beep as confirmation.