NX-8V2 Control 39
LOC PG DESCRIPTION DEFAULT PROGRAMMING DATA
64 24 AUXILIARY 2 0-0 _ _
65 24 KEYPAD PANIC 0-0 _ _
66 24 KEYPAD MULTIPLE CODE ENTRY TAMPER 0-0 _ _
67 24 BOX TAMPER / BOX TAMPER RESTORE 0-0-0-0 _ _ _ _
68 24 AC FAIL / AC RESTORE 0-0-0-0 _ _ _ _
69 24 LOW BATTERY / LOW BATTERY RESTORE 0-0-0-0 _ _ _ _
70 24 POWER SHORT / POWER SHORT RESTORE 0-0-0-0 _ _ _ _
71 24 BELL TAMPER / BELL TAMPER RESTORE 0-0-0-0 _ _ _ _
72 24
TELEPHONE LINE CUT / LINE CUT RESTORE
0-0-0-0 _ _ _ _
73 24
GROUND FAULT / GROUND FAULT RESTORE
0-0-0-0 _ _ _ _
74 24
EXPANDER TROUBLE / EXP TROUBLE RESTORE
0-0-0-0 _ _ _ _
75 24 FAILURE TO COMMUNICATE 0-0 _ _
76 24 LOG FULL COMMUNICATOR CODE 0-0 _ _
77 25 OPENING CODE COMMUNICATOR CODE
Segment 1: Partition 1 Opening Code 0 _
Segment 2: Partition 2 Opening Code 0 _
Segment 3: Partition 3 Opening Code 0 _
Segment 4: Partition 4 Opening Code 0 _
Segment 5: Partition 5 Opening Code 0 _
Segment 6: Partition 6 Opening Code 0 _
Segment 7: Partition 7 Opening Code 0 _
Segment 8: Partition 8 Opening Code 0 _
78 25 CLOSING COMMUNICATOR CODE
Segment 1: Partition 1 Closing Code 0 _
Segment 2: Partition 2 Closing Code 0 _
Segment 3: Partition 3 Closing Code 0 _
Segment 4: Partition 4 Closing Code 0 _
Segment 5: Partition 5 Closing Code 0 _
Segment 6: Partition 6 Closing Code 0 _
Segment 7: Partition 7 Closing Code 0 _
Segment 8: Partition 8 Closing Code 0 _
79 25 AUTOTEST COMMUNICATOR CODE 0-0 _ _
80 25 RECENT CLOSING AND EXIT ERROR 0-0 _ _
81 25
START PROGRAMMING / END PROGRAMMING
0-0-0-0 _ _ _ _
82 25 END DOWNLOAD 0-0-0-0 X X _ _
83 25 CANCEL COMMUNICATOR CODE 0 _
84-87 25 RESERVED 0-0-0-0 Reserved
88 25 PARTITION 1, ACCOUNT CODE 10-10-10-10-10-10 _ _ _ _ _
89 25 PARTITION 2, ACCOUNT CODE 10-10-10-10-10-10 _ _ __ _ _
90 25 PARTITION 2, FEATURE AND REPORTING SELECTION
Segment 1
1 = Quick Arm
2 = Re-Exit
3 = Auto Bypass
4 = Silent Panic
5 = Audible Panic
6 = Auxiliary 1
7 = Auxiliary 2
8 = Multi Keypress Tamper
Segment 2
1 = LED extinguish enable
2 = Require user code for bypassing zones
3 = Bypass sounder alert
4 = AC power/low battery sounder alert
5 = Enables bypass toggle
6 = Enables silent auto arm
7 = Enables auto instant
8 = Reserved
Segment 3
1 = Open/Close
2 = Bypass
3 = Restore
4 = Trouble
5 = Tamper
6 = Cancel
7 = Recent Closing
8 = Exit Error
Segment 4
1 =Late to Close / Early to Open
2-8 =Reserved
Segment 5 RESERVED