Performance Data Sheet
SmartWater Filtration System-GE®MSWF Cartridge
Thissystem has been tested and certified in filter model GEMSWFaccording to NSF/ANSIStandards 42 and 53 for reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to aconcentration lessthan or equal to the permissible limit for water
leaving the system, as specified in NSF/ANSIStandards 42 and 53.* (Safetyfactors built in for unmetered usage.)
Standard No. 42: Aesthetic effects
lnflue,t Challenge
Parameter ' USEPAMCL I Concentration
2.0 mg/L ± 10%
at least 10,000 particles/
mL
Standard No. 53: Health effects
influent Challenge
Parameter
Effluent % Reduction
Average Maximum Average ' Maximum Min, Required Reduction
0.06 mg/L 0.10 mg/L 97% 9.1% ->50%
408,333 670.000 95.5% 89.4% ->85%
Effluent ' % Reduction ' Hax. Permissible
USEPAMCL Concentration Average Maximum Average Maximum
1 NTU.... 11 ± 1 NTU.... 0.38 NTU 0.5 NTU 96.5% 95.4%
99.95% Reduction Minimum 50.000 L < 1#/L 4 #/L > 99.99% > 99.99%
0.010 mg/L 0.15 mg/L ± 10% < 1 ppb < 1ppb 99.3% 99.3%
0.010 mg/L 0.15 mg/L ± 10% 3.1 ppb 9.0 ppb 98.0% 9s.s%
0.002 mg/L 0.006mg/L ± 10% 0.34 ppb 0.7 ppb 94.0% 89.6%
0.002 mg/L 0.006mg/L ± 10% 0.66 ppb 1.5ppb 88.4% 73.7%
0.0002 mg/L 0.002 mg/L ± 10% < 0.02 ppb < 0.02 ppb > 99.0% > 99.0%
0.003 mg/L 0.009 mg/L ± 10% < 0.5 ppb < 0.0Sppb > 93.9% > 94.3%
0.070 mg/L 0.210 mg/L ± 10% 7.7 ppb S5 ppb 96.0% 82.0%
0.003 mg/L 0.015 mg/L ± 10% < 1 ppb < 1 ppb >92.9% > 92.9%
0.005 mg/L 0.015 mg/L ± 10% < 0.5 ppb < 0.5 ppb >96.8% > 97.0%
0.040 mg/L 0.080 mg/L ± 10% < 1ppb 1 ppb > 98.7% > 98.7%
0.075 mg/L 0.225 mg/L ± 10% < 0.Sppb < 0.5 ppb > 99.7% > 99.8%
99% Reduction 107 tel0 8fibers/L; <0.17 NF/L <0.17 NF/L >99% >99%
ifibers > 10pm in length
"Testedusing pressureof 60 psig;pH of7.5+ 0.5;temp of68o+ S°F(20°+ 2.5°C).
"'Measurement in Partides/mL Particles used were 0.5 1microns.
""Based on the useof Cryptosporidium parvum oocysts.
.... NTU Nephelometric Turbidity Units
Product Water
0.5 NTU
99.95%
0.010 mg/L
0.010 mg/L
0.002 mg/L
0.002 mg/L
0.0002 mg/L
0.003 mg/L
0.070mg/L
0.003 mg/L
0.005 mg/L
0.040 mg/L
0.075 mg/L
99% Reduction
Capacity 300gallons (1.135liters).Contaminant reduction determined by NSFtesting.
Application Guidelines/Water Supply Parameters
ServiceFlow
WaterSupply
It isessentialthat the manufacturer'srecommendedinstallation,maintenanceandfilter replacementrequirementsbe carriedout forthe productto performasadvertised.
SeeinsertforWarrantyinformation.
Operating Specifications
• Pressurerequirement: 40 120 psi(2.8 8.2 bar),non shock
• Temperature: 33 100°F(0.6-38°C)
• Flowrate:0.9 gpm (3.14Ipm)
General Installation/Operation/Maintenance Requirements
• Flushnew cartridge at fullflow for4 1/2 gallons(aboutfiveminutes)to purge
trapped air.
• Replacecartridge when flow becomes too slow.
, Protect from freezing by removing filter cartridge when temperatures are
expected to drop below 40°F(4.4°C).Donot install systems in areas where
ambient temperatures may go above IO0°F or below 40°E Do not install
on a hot watersupply.
Special Notices
Installation instructions are includedwith the product when shipped.
This drinking water system must be maintained according to manufacturer's
instructions, including replacement of filter cartridges.
• Donot usewith water that ismicrobiologically unsafe or of unknown quality with
out adequate disinfection before or after thesystem. Systemscertified for cyst
reduction may be used ondisinfected water that may contain filterable cysts,
• The contaminants or other substances removed or reduced by this water
treatment system are not necessarily in your water.
Check for compliance with the applicable state and local laws and regulations.
Note that while the testing was performed under standard laboratory conditions.
actual performance may vary. Systems must be installed and operated in
accordance with manufacturer's recommended procedures and guidelines.
Installation and use MUST comply with all state and local plumbing codes. Do not
install if water pressure exceeds 120 psi. Ifyour water pressure exceeds 80 psi
(552 kPa).you should install a pressure limiting valve. Contact a plumbing
professional if you are uncertain how to check your water pressure.
Do not install where water hammer conditions may occur. If water hammer
conditions exist you must install a water hammer arrester. Contact a plumbing
professional if you are uncertain how to check for this condition.
Where a backflow prevention device is installed on a water system, a device for
controlling pressure due to thermal expansion must be installed.
Forconditions ofuse,health claimscertified by the California Department of Public
Health,and replacements,see performance data sheet. California Department
ofPublic HealthCertification #06 1834.The contaminants or other substances
removed or reduced by this water filter are not necessarilyin all users'water,
Tested and Certified by NSFInternational against ANSI/NSF Standards 42 and 53 in model GE P1SWFfor the reduction of:
Standard No. 42: Aesthetic Effects
, Chemical
Chlorine Tasteand Odor
. Mechanical Filtration
Particulate Reduction. Class]
GE
Appliances
Appliance Park
Louisville, KY40225
geapplianceparts.com
Standard No. 53: Health Effects
, Chemical Reduction
Atrazine Reduction
Endrin Reduction
Benzene and Carbofuran Reduction
1,4 DicNorobenzene and
2,4-D Reduction
Lead and Lindane Reduction
Mercury and Toxaphene Reduction
, Mechanical Filtration
Cystand Asbestos Reduction(_
REPLACEMENT ELEMENT
EPA#20350-MN-005
© 2020 General Electric Company PC61577C