Aboutthe controlsonyourZoneline. ge.com
i
TEMPCONTROL
@
MODECONTROL
@
Co trols
TempControl
The temp control is used to maintain the
I'00111 telllpei'attli'e. The coi/li)i'essoi" will
c_cle on and off to kee I) the room at the
same comfort level. _]_en you tm'n the
knob to COOLER(blue), the indoor air
will become coole_: Tm'n the knob to
WARMER (red) and the indoor air will
become wai_nlei:
3900Series only
_]_en the outdoor temperatm'e is lower
than 90°E heat is provided b)' the electric
heater in the air conditioner insmad of bv
the heat I)ump.
Mode Control
HIGH COOLand LOW COOLpr_vi(le cooling
with different tim speeds.
HIGHHEATand tOW HEATprovide heating
with different tim speeds.
LOWFAN or HIGH FANprovides air
circulation and filtering without cooling
or heating.
NOTE:If youmove the switch from a cool orheat
setting to STOPorto a fan setting, the unit hasan
automatic3-minute delaybeforea//owlbg the
compressorto restart in thecool or heat mode.
About YourHeat Pump (3800 Series only)
Heat l)mnps can save money by removing heat
fl'om the outside ai_e\'en when the outside
temperature is below fl'eezing--and releasing
that heat indom_,
To get the best pex_bmmnce fl'om your heat
I)mnp, don't change the room them/ostat ve_T
often. Raising the heat setting 2-3 degrees will
cause the Zoneline to use its electric heating
elements in order to reach the new temperatm'e
setting quickly.
There is a three minute minimum compressor
run time at any setting to prevent short cycling.
The indoor tim motor stm*s beli)re the
compressor and stops after the compressor
cycles off.
The electric headng elements use much
more electricit_ than heat pmnps and cost
II/OI'e to operate.
Quick Heat Recovery
Activates each time the them_ostat is
switched fl'om STOP or a COOLmode U) a HEAT
mode. Electric heatex_ are energized until the
them_ostat set point is reached. On heat pump
models, the heat pump operation will resume
at the next call for heat.
3