Wire Size and Breaker Size
Warning: All wiring, including installation of the receptacle, must be in accordance with the National
Electric Code, local codes, ordinances, and regulations.
Use only the wiring size recommended for single outlet branch circuit.
Use only the type and size fuse of HACR circuit breaker indicated on the units rating plate. Proper
current protection is the responsibility of the owner.
Recommended branch circuit wire sizes*
Nameplate AWG Wire
maximum circuit size**
breaker size
15A 14
20A 12
30A 10
AWG—American Wire Gauge
* Single circuit breaker from main box
** Based on copper wire, single insulated conductor at 60° C
Note: Use copper conductors only.
Power Supply Kits
Tandem
15 Amp.
Perpendicular
20 Amp.
Large Tandem
30 Amp.
265/230/208 Volt
Power
Supply Kits
Wall Plug
Configuration
Circuit Protective Device
Heater Wattage
@ 230/208 volts
Electrical Requirements
(Continued next page)
RAK3152 Tandem 15 Amp Time Delay Fuse or Breaker 2.61/2.19 KW
RAK3202 Perpendicular 20 Amp Time Delay Fuse or Breaker 3.42/2.87 KW
RAK3302 Large Tandem 30 Amp Time Delay Fuse or Breaker 4.81/4.07 KW
RAK4157 Direct Connect 15 Amp Time Delay Fuse or Breaker 2.61/2.19 KW
RAK4207 Direct Connect 20 Amp Time Delay Fuse or Breaker 3.42/2.87 KW
RAK4307 Direct Connect 30 Amp Time Delay Fuse or Breaker 4.81/4.07 KW
RAK5157 Direct Connect 15 Amp Time Delay Fuse or Breaker 2.61 KW
RAK5207 Direct Connect 20 Amp Time Delay Fuse or Breaker 3.42 KW
RAK5307 Direct Connect 30 Amp Time Delay Fuse or Breaker 4.81 KW