CHAPTER 3: IEC 61850 COMMUNICATION MODEL IMPLEMENTATION CONFORMANCE STATEMENT (MICS)
UR FAMILY – COMMUNICATIONS GUIDE 3-101
3
3.5.2.69 Split phase (SpltPh)
This element is instantiated in the following products: G30, G60.
Table 3-117: Split phase data objects
VISIBLE
STRING255
SP If reference is external to this
IED, mapped to the source’s
GOOSE control block, else empty
string
R/C
cdcNs VISIBLE
STRING255
EX Name of the GE Multilin
namespace at the time of this
firmware release
R
cdcName VISIBLE
STRING255
EX GEORG R
LNName: SpltPhPDIF1 LDevice inst: Prot UR element: Split Phase Element
data obj. data attribute Type FC UR Name Description R/W/C
Mod INC This logical node’s mode R/Ctrl
stVal ENUMERATED ST 1 (on) R
ctlModel CtlModels CF 0 (status only) R
Health INS This logical node’s health R
stVal ENUMERATED ST LPHD1.PhyHealth.stVal R
Str ACD SPLIT PHASE PKP, SPLIT PHASE A PKP,
SPLIT PHASE B PKP & SPLIT PHASE C PKP
operands
R
general BOOLEAN ST SPLIT PHASE PKP R
dirGeneral ENUMERATED ST 0 R
phsA BOOLEAN ST SPLIT PHASE A PKP R
dirPhsA ENUMERATED ST 0 R
phsB BOOLEAN ST SPLIT PHASE B PKP R
dirPhsB ENUMERATED ST 0 R
phsC BOOLEAN ST SPLIT PHASE C PKP R
dirPhsC ENUMERATED ST 0 R
Op ACT SPLIT PHASE OP, SPLIT PHASE A OP, SPLIT
PHASE B OP & SPLIT PHASE C OP
operands
R
general BOOLEAN ST SPLIT PHASE OP R
phsA BOOLEAN ST SPLIT PHASE A OP R
phsB BOOLEAN ST SPLIT PHASE B OP R
phsC BOOLEAN ST SPLIT PHASE C OP R
Dpo SPS SPLIT PHASE DPO operand R
stVal BOOLEAN ST SPLIT PHASE DPO R
DpoPhsφ SPS SPLIT PHASE θ DPO operand R
stVal BOOLEAN ST SPLIT PHASE θ DPO R
BlkRefγ ORG SPLIT PHASE BLK setting for setting group
γ.
R
GEORG R
setSrcRef ObjectReference SP SPLIT PHASE BLK for group γ. reference to the data attribute to input R/C
VISIBLE
STRING255
SP Reference to the ultimate source
of value selected by setting
SPLIT PHASE BLK for setting
group γ.
R/C
setSrcCB ObjectReference SP source GoCB of input if via GOOSE R/C
VISIBLE
STRING255
SP If reference is external to this
IED, mapped to the source’s
GOOSE control block, else empty
string
R/C
LNName: S2AcTmPMSS1 LDevice inst: Prot UR element: SPEED2 Acceleration Time element
data obj. data attribute Type FC UR Name Description R/W/C