CHAPTER 3: IEC 61850 COMMUNICATION MODEL IMPLEMENTATION CONFORMANCE STATEMENT (MICS)
UR FAMILY – COMMUNICATIONS GUIDE 3-173
3
units.multiplier ENUMERATED 0, the code for a multiplier of 1 R
db INT32U CF MMXU# RMS PhV.phsA
DEADBAND
R/W/C
zeroDb INT32U CF voltage cut-off level. R
VbRMS MV SRC # Phase BG Voltage RMS, in primary
volts
R
instMag AnalogueValue MX R
instMag.f FLOAT32 SRC # Phase BG Voltage RMS R
mag AnalogueValue MX R
mag.f FLOAT32 instMag.f deadbanded R
units Unit CF R
units.SIUnit ENUMERATED 29, the code for primary volts (W/A) R
units.multiplier ENUMERATED 0, the code for a multiplier of 1 R
db INT32U CF MMXU# RMS PhV.phsB
DEADBAND
R/W/C
zeroDb INT32U CF voltage cut-off level. R
VcRMS MV SRC # Phase CG Voltage RMS, in primary
volts
R
instMag AnalogueValue MX R
instMag.f FLOAT32 SRC # Phase CG Voltage RMS R
mag AnalogueValue MX R
mag.f FLOAT32 instMag.f deadbanded R
units Unit CF R
units.SIUnit ENUMERATED 29, the code for primary volts (W/A) R
units.multiplier ENUMERATED 0, the code for a multiplier of 1 R
db INT32U CF MMXU# RMS PhV.phsC
DEADBAND
R/W/C
zeroDb INT32U CF voltage cut-off level. R
A WYE SRC # Current phasors, in primary
amperes
R
phsA CMV R
phsA.instCVal Vector MX R
phsA.instCVal.mag
.f
FLOAT32 SRC # Phase A Current
Magnitude
R
phsA.instCVal.ang
.f
FLOAT32 SRC # Phase A Current Angle UR range -180...+180 converted to 0...360R
phsA.cVal Vector MX R
phsA.cVal.mag.f FLOAT32 instCVal.mag.f deadbanded R
phsA.cVal.ang.f FLOAT32 instCVal.ang.f deadbanded R
phsA.units Unit CF R
phsA.units.SIUnit ENUMERATED 5, the code for primary amperes R
phsA.units
.multiplier
ENUMERATED 0, the code for a multiplier of 1 R
phsA.db INT32U CF MMXU# A.phsA .db R/W/C
phsA.dbAng INT32U CF MMXU# A.phsA.dbAng R/W/C
phsA.zeroDb INT32U CF current cut-off level. R
phsB CMV R
phsB.instCVal Vector MX R
phsB.instCVal.mag
.f
FLOAT32 SRC # Phase B Current
Magnitude
R
phsB.instCVal.ang
.f
FLOAT32 SRC # Phase B Current Angle UR range -180...+180 converted to 0...360R
phsB.cVal Vector MX R
phsB.cVal.mag.f FLOAT32 instCVal.mag.f deadbanded R
phsB.cVal.ang.f FLOAT32 instCVal.ang.f deadbanded R
phsB.units Unit CF R
LNName: ACsrcMMXU# LDevice inst: Meter UR element: AC Source #