FF1 Thermistor Test
00 25
FF2 Thermistor Test
00 26
FF Evaporator Thermistor Test
00 27
FZ Cabinet Thermistor Test
00 28
FZ Evaporator Thermistor Test
00 29
Ambient Temp Test
00 30
Deli pan Thermistor Test
00 31
Ice Mold Body (MB) Thermistor Test
00 32
Conv Drawer Thermistor Test
00 36
Ice Mold Body (DB) Thermistor Test
00 37
Ice Cabinet Thermistor Test
00 38
Hot Water 1 Thermistor Test
00 39
Hot Water 2 Thermistor Test
00 40
Humidity Sensor Test
FZ
Display
FF
Display
Mode Comments
These tests perform a check on all sensors
located throughout the unit individually.
Once the test for the thermistors is executed,
the instantaneous temperature of the
thermistor will be displayed in the displays.
If the thermistor is out of range, - - “ will be
displayed.
When reading the temp insert a decimal
between the 2 right digits.
The example reading below of -1077 would be
read as -10.77˚ F.
MB = Main Board, Cabinet
DB = Door Board, LH Door
Service Diagnostics Tests