EasyManuals Logo

GE GEH-6285C User Guide

GE GEH-6285C
27 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #15 background imageLoading...
Page #15 background image
Power
Break
®
\\
Circuit
Breakers
Chapter
3
.
Accessory
Operation
Following
are
the
operation
procedures
for
each
of
the
available
breaker
accessories
.
See
the
user
guides
supplied
with
the
accessories
for
installation
and
removal
.
3
-
2
Plug
-
In
Accessory
Compartment
Several
of
the
accessories
are
installed
in
the
acces
-
sory
compartment
on
the
front
of
the
breaker
.
Figure
7
illustrates
this
compartment
and
the
locations
of
each
of
the
plug
-
in
accessory
modules
.
3
-
1
Lugs
and
Adapters
Direct
-
mounting
lugs
bolt
directly
to
the
line
or
load
strap
of
the
circuit
breaker
.
Lug
catalog
num
-
bers
and
sizes
are
listed
in
Table
5
.
Shunt
Trip
Cat
*
No
*
Wires
Wire
Sizes
Amps
Bell
Alarm
with
Lockout
Bell
Alarm
-
Alarm
Only
#
2
-
600
kcmil
CU
/
AL
1
/
0
-
250
kcmil
CU
/
AL
1
TPLUG
106
m
2
TPLUG
206
2
#
2
-
600
kcmil
CU
/
AL
600
300
-
750
kcmil
CU
/
AL
TPLUG
308
3
800
Undervoltage
Release
300
-
750
kcmil
CU
/
AL
3
THPCLUG
308
800
TPLUG
408
4
500
-
800
kcmil
CU
/
AL
1600
Figure
7
.
Locations
of
plug
-
in
accessory
modules
in
compartment
on
front
of
breaker
.
THPCLUG
408
4
500
-
800
kcmil
CU
/
AL
1600
Table
5
.
Catalog
numbers
of
direct
-
mounting
lugs
.
Bus
adapters
(
T
-
studs
)
bolt
directly
to
the
line
or
load
terminals
of
the
breaker
.
The
catalog
numbers
are
:
3
-
3
Bell
Alarm
-
Alarm
Only
The
Bell
Alarm
-
Alarm
Only
module
,
shown
in
Figure
8
,
provides
a
switch
to
remotely
indicate
that
the
circuit
breaker
has
tripped
.
It
is
reset
either
automatically
when
the
circuit
breaker
is
reclosed
or
manually
when
the
reset
button
on
the
front
of
the
Bell
Alarm
-
Alarm
Only
module
is
pressed
.
In
addition
to
activation
by
protection
trips
,
the
Bell
Alarm
-
Alarm
Only
accessory
module
can
be
set
up
to
interact
with
other
Power
Break
II
accessories
.
DIP
switches
on
the
rear
of
the
Trip
Unit
can
con
-
figure
the
Bell
Alarm
-
Alarm
Only
accessory
to
activate
when
a
Shunt
Trip
or
Undervoltage
Release
trip
occurs
.
The
catalog
numbers
for
the
Bell
Alarm
-
Alarm
Only
are
listed
in
Table
6
.
For
installation
instructions
see
GEH
-
6275
.
SP
08
FCA
and
SP
08
FCC
for
800
A
frames
SP
20
FCA
and
SP
20
FCC
for
1600
A
and
2000
A
frames
Lug
adapters
bolt
directly
to
the
line
or
load
termi
-
nals
on
the
rear
of
the
breaker
.
They
provide
proper
phase
-
to
-
phase
clearances
for
mounting
lugs
.
The
catalog
numbers
are
:
TPLUGA
08
for
800
A
frames
TPLUGA
16
for
1600
A
frames
SPLUGA
20
for
2000
A
frames
(
may
also
be
used
on
1600
A
frames
)
Installation
instructions
for
lugs
and
adapters
are
found
in
GEH
-
4546
.
8
Courtesy of NationalSwitchgear.com

Other manuals for GE GEH-6285C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE GEH-6285C and is the answer not in the manual?

GE GEH-6285C Specifications

General IconGeneral
BrandGE
ModelGEH-6285C
CategoryCircuit breakers
LanguageEnglish

Related product manuals