EasyManuals Logo

GE GEH-6285C User Guide

GE GEH-6285C
27 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #23 background imageLoading...
Page #23 background image
Power
Break
®
II
Circuit
Breakers
Chapter
3
.
Accessory
Operation
Terminal
(
upper
)
Terminal
(
lower
)
1
Auxiliary
12
A
19
Auxiliary
11
A
2
Auxiliary
12
B
20
Auxiliary
11
B
3
Auxiliary
12
common
21
Auxiliary
11
common
4
Auxiliary
10
A
22
Auxiliary
9
A
5
Auxiliary
10
B
23
Auxiliary
9
B
6
Auxiliary
10
common
24
Auxiliary
9
common
7
Auxiliary
8
A
25
Auxiliary
7
A
26
Auxiliary
7
B
8
Auxiliary
8
B
27
Auxiliary
7
common
9
Auxiliary
8
common
10
Auxiliary
6
A
28
Auxiliary
5
A
11
Auxiliary
6
B
29
Auxiliary
5
B
Figure
22
.
Door
Interlock
accessory
installed
on
breaker
.
12
Auxiliary
6
common
30
Auxiliary
5
common
Opening
Door
with
Breaker
Off
To
open
the
enclosure
door
when
the
breaker
is
OFF
,
pull
up
on
the
padlock
tab
and
slide
the
Door
Interlock
lever
counter
-
clockwise
until
it
no
longer
obstructs
the
door
.
When
the
door
is
reclosed
,
sim
-
ply
slide
the
lever
back
into
the
locking
position
.
Opening
Door
with
Breaker
On
The
Door
Interlock
can
be
defeated
,
to
allow
open
-
ing
the
enclosure
door
with
the
breaker
ON
,
even
though
the
padlock
tab
cannot
be
lifted
.
Depress
the
interlock
spring
with
a
screwdriver
in
the
slot
on
the
top
of
the
locking
lever
and
push
the
lever
counter
-
clockwise
to
disengage
it
from
the
spring
.
Remove
the
screwdriver
,
then
continue
rotating
the
locking
lever
until
it
clears
the
door
.
13
Auxiliary
4
A
31
Auxiliary
3
A
14
Auxiliary
4
B
32
Auxiliary
3
B
15
Auxiliary
4
common
33
Auxiliary
3
common
16
Auxiliary
2
A
34
Auxiliary
1
A
17
Auxiliary
2
B
35
Auxiliary
1
B
18
Auxiliary
2
common
36
Auxiliary
1
common
Table
15
.
Auxiliary
switch
positions
on
the
terminal
board
on
the
left
side
of
the
breaker
.
3
-
13
Door
Interlock
The
Door
Interlock
,
shown
in
Figure
22
,
prevents
the
casual
opening
of
the
enclosure
door
,
particu
-
larly
while
the
breaker
is
ON
.
The
catalog
number
of
the
Door
Interlock
is
SPDIL
.
For
installation
instructions
see
GEH
-
6276
.
3
-
14
Push
Button
Cover
Operation
The
Door
Interlock
prevents
the
opening
of
the
enclosure
door
unless
the
locking
lever
is
disen
-
gaged
.
The
lever
can
be
disengaged
easily
with
the
breaker
OFF
or
with
somewhat
greater
diffi
-
culty
with
the
breaker
ON
,
as
described
below
.
The
Push
Button
Cover
,
shown
in
Figure
23
,
pre
-
vents
accidental
or
unauthorized
closing
or
open
-
ing
of
the
circuit
breaker
with
the
local
push
but
-
tons
.
It
consists
of
two
unbreakable
,
individually
sealable
Lexan
®
shields
,
one
over
the
PUSH
ON
button
and
one
over
the
PUSH
OFF
button
.
The
catalog
number
is
SPPBCOVER
.
For
installation
instructions
see
GEH
-
6282
.
16
i
Courtesy of NationalSwitchgear.com

Other manuals for GE GEH-6285C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE GEH-6285C and is the answer not in the manual?

GE GEH-6285C Specifications

General IconGeneral
BrandGE
ModelGEH-6285C
CategoryCircuit breakers
LanguageEnglish

Related product manuals